Desa AND VM42 Installation, Continued, CAUTION Do not kink flexible gas line, M36B,H/VM36B,H

Models: AND VM42

1 30
Download 30 pages 43.9 Kb
Page 12
Image 12
 CAUTION: Do not kink flexible gas line.

12

INSTALLATION

Optional Wireless Hand-Held Remote Control Installation (Cont.) Gas Line Hook-Up

INSTALLATION

Continued

4.Connect wires to control circuit. Connect white wire to termi- nal marked TH/TP on control valve. Connect red wire to male blade connector provided at open end of safety circuit wiring (see Wiring Diagram, page 20).

5.Locate the battery clip mounted on the back of the receiver (see Figure 16).

6.Slide 9-volt battery (not included) through the clip. Note: Only use alkaline battery.

7.Attach the terminal wires to the battery (see Figure 16).

8.Replace refractory brick access panel.

 

9-Volt Battery

Battery

Receiver

Clip

 

Terminal

 

Wires

 

Figure 16 - Installing Battery in Receiver

Installing 9-Volt Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to the battery (not included). Place bat- tery into the battery housing. Note: Only use alkaline battery.

3.Replace battery cover onto remote control unit.

Battery

Remote

Cover

Control Unit

Terminal Wires Manual background

9-Volt Battery

Manual background Battery

Housing

Figure 17 - Installing Battery in Hand-Held Remote Control Unit

GAS LINE HOOK-UP

Manual background WARNING: Gas line hookup should be done by your gas supplier or a qualified service person.

Manual background WARNING: Before you proceed, make sure your gas supply is OFF.

A manual shutoff valve has been included in the appliance’s gas supply system. You may consider installing an extra gas shutoff valve outside the appliance’s enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 18.

In conformance with local codes, route a 1/2" NPT gas line to the appliance through hole in left side of firebox or sub-floor as shown in Figure 19.

Manual background CAUTION: Do not kink flexible gas line.

Typical Exterior Wall Gas

Shutoff

Shutoff Installation

Valve

Key

 

 

Extension

Figure 18 - Manual Shutoff Valve Installation

1/2" NPT Incoming

Black Iron Gas Line

A

7"

7"

Alternate Gas Supply Through Sub-Floor

 

M36(B,H)/VM36(B,H)

M42(B,H)/VM42(B,H)

A

8 5/8" (219mm)

10 1/2" (267mm)

 

 

 

Figure 19 - Routing Incoming Gas Line

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundFor moreManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

108795-01K

Page 12
Image 12
Desa AND VM42 Installation, Continued, CAUTION Do not kink flexible gas line, M36B,H/VM36B,H, M42B,H/VM42B,H