Beep/Symptom

 

FRU/Action

 

 

 

1-2-1

1.

System Board

(Programmable

 

 

Interval Timer failed)

 

 

 

 

 

1-2-2

1.

System Board

(DMA initialization

 

 

failed)

 

 

 

 

 

1-2-3

1.

System Board

(DMA page register

 

 

write/read failed)

 

 

 

 

 

1-2-4

1.

DIMM

(RAM refresh

2.

System Board

verification failed)

 

 

 

 

 

1-3-1

1.

DIMM

(1st 64K RAM test

2.

System Board

failed)

 

 

 

 

 

1-3-2

1.

DIMM

(1st 64K RAM parity

2.

Processor

test failed)

3.

System Board

 

 

 

 

1-4-3

1.

System Board

(Interrupt vector

 

 

loading test failed)

 

 

 

 

 

2-1-1

1.

System Board

(Secondary DMA

 

 

register failed)

 

 

 

 

 

2-1-2

1.

System Board

(Primary DMA register

 

 

failed)

 

 

 

 

 

2-1-3

1.

System Board

(Primary interrupt

 

 

mask register failed)

 

 

 

 

 

2-1-4

1.

System Board

(Secondary interrupt

 

 

mask register failed)

 

 

 

 

 

2-2-1

1.

System Board

(Interrupt vector

 

 

loading failed)

 

 

 

 

 

2-2-2

1.

System Board

(Keyboard controller

2.

Keyboard

failed)

 

 

 

 

 

2-2-3

1.

Battery

(CMOS power failure

2.

System board

and checksum checks

 

 

failed)

 

 

 

 

 

2-2-4

1.

Battery

(CMOS configuration

2.

System board

info validation failed)

 

 

 

 

 

2-3-1

1.

Jumper on J28

(Screen initialization

2.

System Board

failed)

 

 

 

 

 

112Hardware Maintenance Manual: xSeries 220