IBM XSERIES 220 Error Code/Symptom FRU/Action 062, Run Configuration/Setup, 101, 102 System Board

Models: XSERIES 220

1 178
Download 178 pages 10.08 Kb
Page 126
Image 126

Error Code/Symptom

 

FRU/Action

 

 

 

 

062

(Three

1.

Run Configuration/Setup

consecutive boot failures

2.

Battery

using the default

 

 

3.

System Board

configuration.)

 

 

 

4.

Microprocessor

 

 

 

 

101, 102, 106

 

1.

System Board

(System and microprocessor

 

 

error)

 

 

 

 

 

 

 

111

 

1.

Failing adapter

(Channel check error)

2.

DIMM

 

 

 

 

3.

System board

 

 

 

 

114

 

1.

Failing adapter

(Adapter read-only memory

2.

Run diagnostics

error)

 

 

 

 

 

 

 

 

129

 

1.

Microprocessor

(Internal cache error)

2.

Optional microprocessor (if installed)

 

 

 

 

 

 

151

 

1.

Run Diagnostics

(Real time clock error)

2.

Battery

 

 

 

 

3.

System Board

 

 

 

 

161

 

1.

Run Configuration/Setup

(Real time clock battery error)

2.

Battery

 

 

3.

System Board

 

 

 

 

162

 

1.

Run Configuration/Setup

(Device Configuration Error)

2.

Battery

Note: Be sure to load the

3.

Failing Device

default settings and

4.

System Board

any additional

desired settings; then,

 

 

save the configura-

 

 

tion.

 

 

 

 

 

 

 

163

 

1.

Run Configuration/Setup

(Real-Time Clock error)

2.

Battery

 

 

 

 

3.

System Board

 

 

 

 

164

 

1.

Run Configuration/Setup

(Memory configuration

2.

DIMM

changed, see "Memory

3.

System Board

Settings" on page 32.)

 

 

 

 

175

 

1.

System Board

(Hardware error)

 

 

 

 

 

 

 

176, 177, 178

(Security

1.

Run Configuration/Setup

hardware error)

 

2.

System Board

 

 

 

 

 

 

184

 

1.

Run Configuration/Setup

(Power-on password

2.

System Board

corrupted)

 

 

 

 

 

 

 

 

120Hardware Maintenance Manual: xSeries 220

Page 126
Image 126
IBM XSERIES 220 manual Error Code/Symptom FRU/Action 062, Run Configuration/Setup, 101, 102 System Board, Failing adapter