Item

 

Function/Set Value

Initial Value

1 Alarm 1/Alarm 2

(Continued)

 

 

Message Packet

For setting whether to send alarm packets to the PC when there

Not Available

 

 

is alarm input.

 

 

 

 

Not Available : Do not send alarm packets.

 

 

 

Available

: Send alarm packets.

 

 

Alarm FTP

For operation according to the [Alarm FTP] in the FTP Client

Not Available

 

 

feature when there is alarm input. Please refer to FTP Client

 

 

 

Settings (Page 50) for details on alarm FTP.

 

 

 

Set Values: Available, Not Available

 

 

Shutdown

Set to "Available" to quit all operations upon alarm input. Using

Not Available

 

 

this Shutdown function enables operations of this camera to

 

 

 

end safely even during recording into CF cards.

 

 

 

Not Available : Do not shut down.

 

 

 

Available

: Shut down.

 

 

 

Note

 

 

 

 

• When this is set to "Available", all alarm input except alarm

 

 

 

output and message packets will be disabled.

 

 

 

 

 

2 Relay Alarm

Set here to enable the relay alarm function, which is activated

Not Available

 

 

when 2 alarms are received within a preset time interval.

 

 

 

The sequence and time interval for the alarm input can be specified.

 

 

 

When [Alarm Output] is selected, alarm signal output will be

 

 

 

sent to the alarm output terminal on the ceiling mount accord-

 

 

 

ing to the output port settings.

 

 

 

Notes

 

 

A second alarm input enables this relay alarm function, and alarm will not be activated for this second input.

Unless the alarm output in the "Alarm Output" tab is

enabled, this function will not be activated even if alarm output is selected in the alarm input settings. (Page 41)

Alarm Output * Please refer to the [Alarm 1/2] item for details on the set val- *Please

• Go to a preset position

ues.

refer to

• Return Mode

 

the [Alarm

• Interval

 

1/2] item

• Black & White

 

for the

• Message Packet

 

initial

• Alarm FTP

 

values.

• Shutdown

 

 

3 Retry (1 to 3)

For setting the no. of times alarm notification is to be sent to

1

 

the "V.Networks Controller". (Set Value: 1 to 3)

 

Note

Alarm notification may fail, depending on the LAN environment in use. If it fails, set the value for alarm notification to "3". In this case, alarm by the "V.Networks Controller" itself is set off only once.

39

Page 39
Image 39
JVC VN-C625 manual Alarm 1/Alarm Message Packet, Available, Alarm FTP, Shutdown, Relay Alarm, Interval Black & White