Preparation (Step 1 Connection/Installation)

1-1 Connecting Cables (Continued)

2. Connection to Alarm Input/Output Terminal

1 2

Flathead

Alarm Signal

ScrewdriverCable

3

Flathead

Screwdriver

4

1

Connect the alarm input/output terminals to external devices such as sensors and buzzers.

1Loosen the screws on both edges of the terminal block using a flathead screwdriver, followed by dismantling it as shown in the left diagram.

2Strip the coating of the alarm signal cable by about 4mm before inserting it into the terminal.

3Turn the screw on the side to fasten the alarm signal cable.

4Upon fastening the alarm signal cable, re- install the terminal block that has been dismantled in Step 1.

Note

Cable Specifications

50 m or shorter in length UL1007, UL1015 or equivalent AWG#22 to AWG#18 or equivalent

Caution

 Alarm Input Terminal

Sensor

 

 

 

VN-C625

 

 

Connection

 

 

Example (1)

DC12V

 

 

 

 

VCC

 

Terminal

 

R

 

 

1 or 2

 

R

 

OUT

 

 

 

 

12V

1.2mA

 

 

Grounding GND

 

 

Terminal

 

 

Due to external noise, the cable may not function properly even when the cable length is less than 50 m. In this case, use a shielded cable or take measures such as keeping the cable away from the noise source.

Connect this terminal to an infrared, door or metallic sensor, or to a manual switch.

Input Requirements

No-voltage relay or NPN open collector input

The polarity of input detection can be selected

 

via software

(Alarm Input Equivalent Circuit)

Sensor

Connection

Example (2)

Relay, switch,

etc.

OUT

GND

Make/Break/Toggle (at least 250 ms)

Circuit current at low-level: 1.2 mA

Voltage applied at high level: 12 V

16

Page 16
Image 16