Viking F21287A EN manual Vcwh Chimney Wall Hoods 30, 36, 42, 48, 54

Page 8

Dimensions & Specifications

(VCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, & 60”)

Clearance Dimensions

(VCWH Chimney Wall Hoods)

 

A (Duct width)

30”W.

 

12“ (30.5 cm)

36”W.

 

12“ (30.5 cm)

42”W.

 

12“ (30.5 cm)

48“W.

 

18“ (45.7 cm)

60”W.

 

24“ (61.0 cm)

66”W.

 

24“ (61.0 cm)

 

B (Hood width)

30”W.

 

29-7/8“ (76.2 cm)

36”W.

 

35-7/8” (91.1 cm)

42”W.

 

41-7/8” (106.4 cm)

48“W.

 

47-7/8” (121.6 cm)

60”W.

 

59-7/8” (152.1 cm)

66”W.

 

65-7/8” (167.3 cm)

6”

(15.

 

2

cm)

 

B

A

12”

(30.

 

 

5

cm)

 

 

to

24”

(61.

 

 

0

cm)

 

 

18”

(45.

 

 

7

cm)

 

24”

 

.0

cm)

(61

 

 

 

(167. .

66”min

cm)

NOTE: Optional duct cover sold separately.

VCWH Chimney Wall Hoods

Description

30”

36”

42”

48”

60”

Duct cover width

12” (30.5 cm)

12” (30.5 cm)

12” (30.5 cm)

18” (45.7 cm)

24” (61.0 cm)

Duct cover depth

 

 

12” (30.5 cm)

 

 

Duct cover height

 

12” (30.5 cm) to 24” (61.0 cm)

 

Number of filters

2

2

2

2

3

Heat lamps

1

1

1

2

3

Interior ventilator kits

VINV300/600

VINV300/600

VINV600

VINV1200*

VINV1200*

Exterior ventilator kits

DEV900/

DEV900/

DEV900/

DEV1200*/

DEV1200*/

 

1200*

1200*

1200*

1500**

1500**

In-line ventilator kits

DIL1200

DIL1200

DIL1200

DIL1200

DIL1200

Interior duct size

7” (17.8 cm)

7” (17.8 cm)

7” (17.8 cm)

10” (25.4 cm)

10” (25.4 cm)

Exterior duct size

 

 

10” (25.4 cm)

 

 

Interior—Maximum amps

4.2/5.2

4.2/5.2

5.2

10.8

10.8

Exterior—Maximum amps

8.0/5.3

8.0/5.3

8.0/5.3

7.8/8.5

7.8/8.5

In-Line—Maximum amps

5.3/7.2

5.3/7.2

5.3/7.2

9.6

10.0

*A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char- grill. Max duct run is 50 ft (15.2 m).

**It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m). NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.

to

 

.

 

 

 

(76 .

.

 

30”min2

(18272”max.

 

cm)

9

 

 

cm)

to

 

(91.

.

 

 

36”max4

 

 

 

cm)

36”

(91

.4

cm)

 

 

 

 

 

 

14

15

Image 8
Contents Installation Guide Table of Contents Dimensions & Specifications VWH 10’ H./12H. Wall Hoods w/Standard VentilatorVWH 10 H./12H. Wall Hoods w/Standard Ventilator 30 29-7/8 75.9 cm 35-7/8 91.1 cmInterior Ventilator Dimensions CFM Interior Ventilator InstallationVWH 10 H./12H. Wall Hoods w/Standard Ventilator VWH 10 H./12H. Wall Hoods w/Standard Ventilator Top View VWH 18H. Wall Hoods VWH 18H. Wall Hoods VWH 18H Deep Wall Hoods 30, 36, 42, 48 15/16 15.1 cm 10 25.4 cm dia. duct location Exterior Ventilator DimensionsVWH 18H. Wall Hoods Top View Vwho 18H. Outdoor Wall Hoods Vwho 18H. Outdoor Wall Hoods 36, 48Vwho 18H. Outdoor Wall Hoods 182Vcwh Chimney Wall Hoods Vcwh Chimney Wall HoodsVcwh Chimney Wall Hoods 30, 36, 42, 48, 54 Cm dia Duct location 10 25.4 cm dia Duct locationSupply 15.2 cmVcih Chimney Island Hoods Vcih Chimney Island HoodsVcih Chimney Island Hoods 36, 42, 54 Power 15.2 cm 10 25.4 cm dia Duct locationCustom Hood Canopy Cutouts Custom Hood Canopy Bottom Cutout DimensionsVbcv Wall Custom Ventilator System 36, 42, 48 Vbcv Wall Custom Ventilator System Vbcv Wall Custom Ventilator System25.4 cm Dia. duct locationCheck Framing Installation VWH 10 H./12H. Wall Hoods w/Standard Ventilator Installation Duct Cover OptionVWH 10 H./12H. Wall Hoods w/Standard Ventilator VWH 10 H./12H. Wall Hoods w/Recirculating KitInstallation con’t VWH 18H. Wall & Vcwh Chimney Wall HoodsDuct Cover Option VWH 18H. Wall Hoods Duct Cover Option Vcwh Chimney Wall HoodsInstallation Vcih Island Hoods Mounting optionsService & Registration Viking RANGE, LLC Preferred Service