Viking F21287A EN manual Installation con’t, VWH 18H. Wall & Vcwh Chimney Wall Hoods

Page 17

Installation (con’t)

(VWH 10” H./12”H. Wall Hoods w/Recirculating Kit)

8

BARE OR GREEN

 

9

 

 

 

 

1

1

 

 

 

2

 

 

GREEN

 

 

 

 

 

 

 

BLACK

 

 

 

WHITE

 

 

 

 

WHITE

BLACK

 

 

 

 

 

 

Installation

(VWH 18”H. Wall & VCWH Chimney Wall Hoods)

1

1-

 

2

 

13/16 6

 

1-1/2”x 3/4”

(4.

 

 

 

Slot for

 

 

cm)

 

(3.8 cm) x (1.9 cm)

 

5/16”

wood strip

5/16”

wood strip

 

 

nut driver

 

nut driver

 

 

 

Connect black to black, white to white, and the

Replace electrical box cover. Make connection to

green/bare wire under the green screw.

breaker box.

NOTE: Housing wiring must be properly installed for

 

wiring to be correct when wiring unit.

 

10

11

 

1

Measure down 1-13/16 (4.6 cm) from desired height of hood and secure 1-1/2” x 3/4” wood strip (provided locally) to wall using screws provided.

3

5/16” nut driver

Use additional mounting screws to secure hood to

wood strip.

5/16”

nut driver

Assemble brackets to baffles and insert charcoal filters.

12 1

2

Slide spacer front over front lip. Push spacer rear up,

then slide back over rear lip.

2

3

 

Slide filter front over front lip. Push filter rear up, then

slide back over rear lip.

13 1

2

3

 

Slide filter front over front lip. Push filter rear up, then

slide back over rear lip.

CAUTION: Secure vent hood to wall using screws provided. Use additional mounting screws and wall anchors, if necessary.

4

3

2

Slide filter front over front lip. Push filter rear up, then

slide back over rear lip.

CAUTION: If not using a duct cover, using screws provided, make sure top mounting screws are secured into soffit or cabinet framing use additional mounting screws, if necessary.

5

1

3

2

Slide filter front over front lip. Push filter rear up, then

slide back over rear lip.

32

33

Image 17
Contents Installation Guide Table of Contents VWH 10’ H./12H. Wall Hoods w/Standard Ventilator Dimensions & SpecificationsVWH 10 H./12H. Wall Hoods w/Standard Ventilator 30 29-7/8 75.9 cm 35-7/8 91.1 cmCFM Interior Ventilator Installation Interior Ventilator DimensionsVWH 10 H./12H. Wall Hoods w/Standard Ventilator VWH 10 H./12H. Wall Hoods w/Standard Ventilator Top ViewVWH 18H. Wall Hoods VWH 18H. Wall HoodsVWH 18H Deep Wall Hoods 30, 36, 42, 48 15/16 15.1 cm 10 25.4 cm dia. duct location Exterior Ventilator DimensionsVWH 18H. Wall Hoods Top View Vwho 18H. Outdoor Wall Hoods 36, 48 Vwho 18H. Outdoor Wall HoodsVwho 18H. Outdoor Wall Hoods 182Vcwh Chimney Wall Hoods Vcwh Chimney Wall HoodsVcwh Chimney Wall Hoods 30, 36, 42, 48, 54 10 25.4 cm dia Duct location Cm dia Duct locationSupply 15.2 cmVcih Chimney Island Hoods Vcih Chimney Island HoodsVcih Chimney Island Hoods 36, 42, 54 15.2 cm 10 25.4 cm dia Duct location PowerCustom Hood Canopy Cutouts Custom Hood Canopy Bottom Cutout DimensionsVbcv Wall Custom Ventilator System 36, 42, 48 Vbcv Wall Custom Ventilator System Vbcv Wall Custom Ventilator System25.4 cm Dia. duct location Check Framing Installation VWH 10 H./12H. Wall Hoods w/Standard Ventilator Duct Cover Option InstallationVWH 10 H./12H. Wall Hoods w/Standard Ventilator VWH 10 H./12H. Wall Hoods w/Recirculating KitVWH 18H. Wall & Vcwh Chimney Wall Hoods Installation con’tDuct Cover Option Vcwh Chimney Wall Hoods Duct Cover Option VWH 18H. Wall HoodsMounting options Installation Vcih Island HoodsViking RANGE, LLC Preferred Service Service & Registration