I M P O RTA N T N OT E
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
W O L F COOKTOP VENTILATION HOODS
WALL HOOD I N S TA L L AT I O N
E L E C T R I C A L C O N N E C T I O N S
IMPORTANT NOTE: This ventilation hood must be properly grounded. This unit should be installed by a qualified electrician in accord- ance with all applicable national and local electrical codes.
Remove the cover from the rear electrical box. Remove the electrical box knockout that faces the hood's discharge collar.
Insert 6" (152) of 120 V AC power cable through the knockout opening. Secure the cable to the electrical box with an appropriate connector.
Make electrical connections. Connect black to black, white to white and green/yellow to green or bare wire. Refer to the illustration below.
Reinstall the electrical box cover and screws. Make sure that all wires are secure and that no wires are pinched between the cover and box.
Refer to page 13 for internal blower installation guidelines and remote blower wiring.
C O N N E C T D U C T W O R K
Use the screws and wall anchors provided to secure the upper brackets to the ceiling. Position the upper brackets based on the dimension of the telescopic chimney flue.
Use an 8" (203) round metal duct to connect the duct collar on the hood to the ductwork above. Use duct tape to make all joints secure and air tight.
Connect the upper section of the telescopic chimney flue to the brackets with the screws provided.
Nest the bottom of the telescopic chimney flue into the relief in the hood shell.
green/yellow to |
|
|
| ||
green or |
|
| black to | ||
bare wire | rear | black 120 V AC | |||
|
| power cable | |||
| electrical | ||||
|
|
| |||
| box |
|
|
| |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fasten upper brackets to ceiling and wall with screws (and anchors if necessary)
Upper
Brackets
Fasten flue to hood and upper brackets
and nest flue in hood relief
Screws
white | discharge |
to white | collar |
HOOD FRONT | TOP OF HOOD SHELL |
Electrical connections | Upper bracket installation |
| Telescopic chimney flue installation |
8