Wolf Ventilation Hood installation instructions T E R N a L B L O W E R I N S TA L L AT I O N

Page 13

INSTALLATION I N S T R U C T I O N S

INTERNAL B L O W E R S

I N T E R N A L B L O W E R I N S TA L L AT I O N

IMPORTANT NOTE: For mounting and installation of the internal blower, refer to the specific installation instructions provided with each blower.

1)Remove the hood filters.

2)Lift the blower into position inside the hood.

3)Use four hex nuts provided with the blower to fasten the unit to four threaded studs.

4)Plug the blowers' single power cord (double for 900 CFM) into the receptacle(s) inside the hood. Use the clip on the hood to keep excess power cord away from moving parts.

5)Reinstall the hood filters.

IMPORTANT NOTE: Before turning the power on, make sure the blower is in the OFF position.

REMOTE B L O W E R S

R E M OT E B L O W E R I N S TA L L AT I O N

IMPORTANT NOTE: For mounting and installation of the remote blower, refer to the specific installation instructions provided with each blower.

Locate the remote blower so that the length of the duct run and number of elbows and transitions are kept to a minimum. Wolf recommends the maximum linear duct run be no greater than 50' (15 m). If possible, the blower should be located between wall studs or roof rafters.

Refer to the illustrations below for overall dimensions of Wolf remote blowers. Refer to installation instructions provided with each blower to verify wall or roof cut-outs.

Avoid pipes, wires or other ductwork that may be running through the wall.

Be sure that there is enough space for any transitions that may be needed between the blower and the connecting ductwork. For best performance, locate transitions nearest the blower.

 

203/4"

 

281/4"

(527)

 

 

 

(718)

10" (254)

 

 

 

 

DIAMETER

 

151/2"

 

241/2"

(394)

 

 

 

(622)

 

14"

 

 

(356)

 

 

243/4"

43/4"

 

(121)

 

(629)

 

 

18" (457)

 

10"

291/2"

(254)

(749)

 

10" (254)

 

DIAMETER

 

143/4"

291/2"

(375)

(749)

101/8"

 

(257)

 

22"

71/4"

(559)

(184)

 

21" (533)

 

10"

291/2"

(254)

 

(749)

 

10" (254)

 

DIAMETER

 

143/4"

291/2"

(375)

(749)

 

103/8"

 

(264)

 

25"

71/4"

(635)

(184)

Remote blower dimensions –

Remote blower dimensions –

600 CFM (801640) and 900 CFM (801641)

1200 CFM (801642)

Remote blower dimensions – 1500 CFM 804701)

13

Image 13
Contents Installation Instructions Page Model Number Serial Number L F Cooktop Ventilation Hoods L C U L AT E C H I M N E Y F L U E H E I G H T Installation I N S T R U C T I O N S Hood P L a C E M E N TS TA L L D U C T W O R K U N T I N G H a R D WA R E I N C L U D E DS TA L L B a C K S P L a S H E C T R I C a L R E Q U I R E M E N T SS TA L L M O U N T I N G B R a C K E T S S TA L L T H E H O O DN N E C T D U C T W O R K E C T R I C a L C O N N E C T I O N SIsland hood installation N N E C T D E C O R AT I V E F L U E S TA L L S U P P O RT S Y S T E MDecorative Flue Support Nuts Frame Weld Screws on Hood U N T H O O D to S U P P O RT F R a M EM OT E B L O W E R S T E R N a L B L O W E R SWA L L S H I E L D S U E E X T E N S I O N SM OT E B L O W E R I N S TA L L AT I O N T E R N a L B L O W E R I N S TA L L AT I O NM OT E B L O W E R W I R I N G Troubles H O O T I N G YO U N E E D Service 7 5 7 0 0