KitchenAid RANGE HOOD LINER with INTERNAL BLOWER Installation Instructions, Prepare Location

Page 7

Electrical Requirements

IMPORTANT: The hood must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition, or Canadian Electrical Code, CSA C22.1, latest edition.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park, Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575

A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this hood be provided.

Do not ground to a gas pipe.

Check with a qualified electrician if you are not sure range hood is properly grounded.

Do not have a fuse in the neutral or ground circuit.

The range hood must be connected with copper wire only.

The range hood should be connected directly to the fused disconnect (or circuit breaker) box through flexible armored or nonmetallic sheathed copper cable.

A UL- or CSA-listed strain relief must be provided at each end of the power supply cable. Wire sizes (copper wire only) and

connections must conform with the rating of the appliance as specified on the model/serial rating plate.

Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70, latest edition, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91, latest edition, and all local codes and ordinances.

INSTALLATION INSTRUCTIONS

Prepare Location

Cover countertop or cooking surface with a thick, protective covering to prevent damaging them.

WARNING

Excessive Weight Hazard

Use two or more people to move and install range hood. Failure to do so can result in back or other injury.

1.Mark the locations of the four ⁷⁄₃₂" (5.6 mm) dia. holes on the hood support as shown.

2³⁄₄"

A

(7.0 cm)

B

wall

17⁵⁄₁₆"

 

(44.0 cm)

⁷⁄₃₂" (5.6 mm)

 

2.Drill the four holes.

3.Provide a rectangular clearance hole for the blower motor housing.

2³⁄₄"

A

wall

(7.0 cm)

 

B

 

 

 

C

 

Hood size

A

B

C

36"

(91.4 cm)

28" (71.1 cm)

14" (35.5 cm)

16" (40.6 cm)

48"

(121.9 cm)

36" (91.4 cm)

18" (45.7 cm)

14¹⁄₂" (36.8 cm)

 

 

 

 

 

Hood size

A

B

36" (91.4 cm)

31⁷⁄₁₆" (79.9 cm)

15²³⁄₃₂" (39.9 cm)

 

 

 

7

Image 7 Contents
9760426A 36 91.4 cm and 48 121.9 cmTable DES Matières Range Hood Liner SafetyImportant Safety Instructions Location Requirements Installation RequirementsInstallation Clearances Tools and Parts48 121.9 cm model Product Dimensions36 91.4 cm model Example vent system Venting RequirementsCalculating Vent System Length Venting MethodsElectrical Requirements Installation InstructionsPrepare Location Hood size 36 91.4 cm 14 ³⁄₁₆ 36.0 cm Make Electrical ConnectionCheck Operation Complete InstallationRange Hood Care Cleaning and MaintenanceAccessories Range Hood USEFor further assistance Requesting Assistance or ServiceIf you need replacement parts For parts, accessories and service in CanadaCall Kitchenaid Ventilation WarrantyWiring Diagram Votre sécurité et celle des autres est très importante Sécurité Doublure DE Hotte DE CuisinièreConservez CES Instructions Outillage et pièces Exigences DinstallationExigences demplacement Espacements dinstallationModèle 48 121,9 cm Dimensions du produitModèle de 36 91,4 cm Exemple de système de décharge Exigences concernant lévacuationCalcul de la longueur effective du circuit dévacuation Méthodes dévacuationSpécifications électriques Préparation de lemplacement Instructions DinstallationDéconnecter la source de courant électrique Raccordement électriqueFonctionnement Achever linstallationCuisinière Contrôle du fonctionnementSurfaces externes AccessoiresRemplacement dune lampe à halogène Nettoyage et entretienPour plus dassistance Demande Dassistance OU DE ServicePour pièces, accessoires et service au Canada Si vous avez besoin de pièces de rechangeGarantie Limitée DE UN AN GarantiedusystèmedeventilationkitchenaidSchéma DE Câblage Page 9760426A