MakeElectrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.Disconnect power.
2.Remove terminal box cover.
3.Remove the knockout in the terminal box cover and install a UL listed or CSA approved ¹⁄₂" strain relief.
4.Run 3 wires, black, white and green, in ¹⁄₂" conduit from service panel to terminal box. Use caulking to seal openings.
5.Attach terminal box to the wall and securely tighten screws.
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in terminal box.
Failure to do so can result in death, fire, or electrical shock.
8.Connect green (or bare) ground wire from home power supply to the unused green ground screw (E) in the terminal box.
9.Tighten strain relief screws.
10.Install terminal box cover.
11.Check all light bulbs to make sure they are secure in their sockets.
12.Reconnect power.
A
E
B
G
C
DF
A.Home power supply cable
B.Black wires
C.UL listed wire connectors
D.White wires
E.Green (or bare) ground wire from home power supply connected to green ground screw
F. Range hood power supply cable
G. Range hood power supply cable connected to green ground screw
6.Use UL listed wire connectors and connect black wires (B) together.
7.Use UL listed wire connectors and connect white wires (D) together.
Install Chimney Covers
For Vented Installations
1.Install damper on top of the exhaust opening. Check that the damper opens freely.
2.Connect the vent system and seal all connections with clamps.
For Non-vented (recirculating) Installations
1.Insert the charcoal filter into the opening behind the grease filters and lock into place. See “Range Hood Care” section.
Install Upper Chimney Cover
1.Slightly spread the sides of the cover apart and hook them behind the chimney mounting brackets.
2.Attach the cover to the brackets with 4 mounting screws.
3.Securely tighten screws.
A
A
A. 4 mounting screws
9