KitchenAid W10118262B Typical flexible connection, Complete Connection, Freestanding Models

Page 12

Typical flexible connection

1.Apply pipe-joint compound made for use with LP gas to the smaller thread ends of the flexible connector adapters (see B and G in the following illustration).

2.Attach one adapter to the gas pressure regulator and the other adapter to the gas shutoff valve. Tighten both adapters.

3.Use a ¹⁵⁄₁₆" combination wrench and channel lock pliers to attach the flexible connector to the adapters. Check that connector is not kinked.

A B C

D

E

 

H G

F

A. Gas pressure regulator

E. Manual gas shutoff valve

B. Use pipe-joint compound.

F. ½" or ¾" gas pipe

 

C. Adapter (must have ½" male

G. Use pipe-joint compound.

pipe thread)

H. Adapter

 

D. Flexible connector

 

 

Complete Connection

1.Locate gas pressure regulator at rear of storage or warming drawer compartment.

NOTE: On models with a warming drawer, an access cover must be removed from the gas pressure regulator.

A

A. Gas pressure regulator

IMPORTANT: Do not remove the gas pressure regulator.

2.Check that the gas pressure regulator shutoff valve is in the “ON” position. The valve is on when the lever is parallel to the floor.

A

4.Test all connections by brushing on an approved noncorrosive leak-detection solution. If bubbles appear, a leak is indicated. Correct any leak found.

5.Remove cooktop burner caps and grates from parts package. Align notches in burner caps with pins in burner base. Burner caps should be level when properly positioned. If burner caps are not properly positioned, surface burners will not light.

C

B

A

A.Burner base

B.Burner cap

C.Burner grate

6.Place burner grates over burners and caps as shown in the following illustration. When properly installed the grates should not overlap the console.

Freestanding Models

A

A. Opening in grate for wok insert to be located over left front burner.

Slide-In Models

A

A. Large flange with rounded corner must be

at rear corner of the cooktop.

A. Gas pressure regulator shutoff valve

3.Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe.

A

B

A. Closed valve

B. Open valve

12

Image 12 Contents
W10118262B Range Safety Table DES MatièresWhat to do if YOU Smell GAS Installation Requirements ToolsandPartsLocation Requirements Mobile Home Additional Installation Requirements Product Dimensions Freestanding RangeMobile home installations require Slide-in RangeInstallation Clearances Freestanding RangesSlide-In Ranges Electrical RequirementsGas Supply Requirements Type of GasGas Supply Line Natural gas Gas Supply Pressure Testing CountertopPreparation Burner Input Requirements Gas Pressure RegulatorInstallation Instructions Unpack RangeMeasureforProperHeight Slide-In RangesAdjust LevelingLegs InstallAnti-TipBracketRemove Warming orStorageDrawer Verify Anti-Tip BracketLocationMake Gas Connection Level RangeTypical flexible connection Complete ConnectionFreestanding Models Slide-In ModelsElectronicIgnitionSystem Adjust Oven Bake Flame if needed Adjust Oven Broil Burner Flame if neededIf flame needs to be adjusted Check Operation of Oven Bake BurnerComplete Installation If you need Assistance or ServiceReplace OvenRacksandWarmingor StorageDrawer To Replace Warming DrawerGAS Conversions LPGas ConversionTo Convert Gas Pressure Regulator Gas pressure regulatorTo Convert Standard Surface Burners To Convert TripleTier Flame Burners on some modelsIgniter electrode Gas tube opening Burner cap Burner base GrooveNatural Gas Conversion To Convert Oven Bake BurnerTo Convert Oven Broil Burner Orifice hood PinTo Convert TripleTier Flame Burner on some models Stamped numberPlate External gas orfice spud Internal gas orifice spud Sécurité DE LA Cuisinière Votre sécurité et celle des autres est très importanteExigences D’INSTALLATION Exigences demplacementOutillageetpièces Dimensions du produit Cuisinière autoportante Cuisinière encastrée³⁄₄ 14,6 cm 30 76,2 cm Dégagements de séparation à respecter Cuisinières autoportantesCuisinières encastrées Spécifications électriques Spécifications del’alimentation engazType de gaz Gaz naturelPréparationduplandetravail Canalisation de gazDétendeur de gaz Débit thermique des brûleursInstructions Dinstallation Déballagede lacuisinièreMesurespourunehauteurappropriée Cuisinières encastréesInstallation dela brideantibasculement Réglage des pieds denivellementVérification de lemplacement delabride Antibasculement Retraitdutiroir-réchaud oudutiroir DeremisageRéglage del’aplomb delacuisinière Retrait du tiroir-réchaudRaccordement à la canalisation degaz Raccordement typique à une canalisation rigideCompléter le raccordement Raccordement typique par raccord flexibleSystèmedallumageélectronique Cuisinière encastréeAllumage initial et réglages des flammes Brûleur TripleTierSi le brûleur ne sallume pas correctement Réglage de la taille des flammesContrôle du fonctionnement du brûleur du four Réglage du brûleur TripleTierRéinstallation du tiroir-réchaud Réinstallation du tiroir de remisageContrôle du fonctionnement du brûleur du gril Sil est nécessaire de régler la taille des flammesAcheverl’installation Si vous avez besoin dassistance ou de serviceConversion pourlalimentationaupropane Si la cuisinière ne fonctionne pas, contrôler ce qui suitConversion du détendeur Conversion des brûleurs standard de la table de cuissonDétendeur Couvercle de plastiqueConversion du brûleur du four Conversion du brûleur du grilPlaque Gicleur externe Gicleur interne Gicleur BrocheConversion pourlalimentationaugaznaturel Chiffre gravé Holes in bracket Trous dans la bride All rights reserved