Electrical connection
The electrical connection to the mains must be made on the appliance. The power voltage and frequency are as indicated on the rating plate.
!THIS APPLIANCE MUST BE EARTHED.
Connecting the power supply cable
To open the terminal board:
•Using a screwdriver, press on the tabs situated on each side of the terminal board cover.
•Pull open the terminal board cover.
To connect the power supply cable, proceed as follows:
•Unscrew the cable clamp screw and the contact screws
•Fasten the wires beneath the screwheads using the following colour scheme: Blue (N) Brown (L)
•Fasten the power supply cable in the corresponding cable clamp and close the cover.
Power cable supply connection to the electrical
mains:GB
We recommend you use a power supply cable which is long enough to allow you to take the oven out of its recess in the event of maintenance operations (only use HAR - H 05 - RRF quality cables fitted with a plug conforming to the regulations in force.
The plug must be accessible at all times.
Unplug the appliance before all operations, even when replacing the oven lamp.
Using the appliance without correct earthing is highly dangerous.
!After connecting the appliance to the flexible cable, tighten all the screws on the terminal board.
APPLIANCE SPECIFICATIONS
Dimensions | width 43.5 cm |
height 32 cm | |
| depth 41.5 cm |
|
|
Volume | 58 l |
Electrical Connection:
4 2 N L
Voltage Frequency: 230
Fuse Section: 16A Supply cable: 3x1.5mm2
Electrical | voltage: 230 - 240 V~ 50/60 Hz | |
(see data plate) | ||
connections | maximum power absorbed | |
| ||
|
|
|
| Directive 2002/40/EC on the label | |
| of electric ovens. Standard EN 50304 | |
ENERGY | Declared energy consumption | |
LABEL* | for Forced convection Class – | |
| heating mode: | |
| ECO. |
You can connect your oven to the system means of a terminal board. Refer to above information for the minimal cable sections and the calibration of the protective elements according to the connection.
If the appliance is installed with a junction box, an omnipolar circuit breaker - with a minimum contact opening of 3mm - should be installed between the appliance and the mains.
* Without removable guide rails
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
3