Wells WVOC-G136 operation manual Ventilator Operation, PRE-FILTER Element

Page 15

509 305936 OpM WVOC-G136

VENTILATOR OPERATION

1.Press the VENTILATOR POWER switch to ON. The green VENTILATOR POWER light will glow and the blower fan will start. After a short time, if all filters are sensed as being in position and not clogged, the griddle will be energized. The roll warmer is energized at all times.

During normal operation, the VENTILATOR POWER light will be the only light glowing on the upper control panel.

2.If the amber CHECK FILTER light glows, one or more filter elements is out of position. Check the GREASE BAFFLE, PRE-FILTER and FILTER PACK for proper installation in their respective positions. Grease baffle and filter pack position are sensed by mechanical switches. Pre-filter position is sensed by a vacuum switch.

3.When the amber REPLACE PRE-FILTERlight glows, the pre-filter is nearing the end of its service life. Replace the disposable

PRE-FILTER ELEMENT.

4.When the amber REPLACE FILTER PACK light illuminates, the HEPA / Charcoal filter pack is nearing the end of its service life. Replace the FILTER PACK.

Note: The REPLACE PRE-FILTER and REPLACE FILTER PACK lights are a warning that the indicated filter is near the end of its service life. The appliance will continue to operate for a period of time after the light glows to allow continued operation through a peak period. However, the indicated filters must be replaced within a reasonably short time period or they will clog and shut down electrical power to the griddle. The ventilator blower will continue to run.

5.When the red SERVICE REQUIRED light glows, either the pre-filter or filter pack (or both) is clogged and can no longer pass sufficient air to allow further operation. The ventilator fan continues to run, but the griddle is shut down until the underlying clogged filter situation has been corrected. This can occur when neither CHANGE...FILTER indicator light is lit, if both pre-filter and filter pack are marginal. Replacing both the pre-filter and the filter pack will remedy the situation.

Note: replacing the pre-filter, even though not very dirty, will often extend the service life of the more expensive filter pack.

Reset the unit by turning the VENTILATOR POWER switch to OFF, then back ON.

6.A failure of incoming electrical power will cause a shut down of the unit. After power is restored, reset the unit by turning the VENTILATOR POWER switch to OFF, then back ON.

OPERATION

CAUTION:

HOT SURFACE

Exposed surfaces can be hot to the touch and may cause burns.

NOTE:

Fig. 8 Ventilator Indicator and Warning Lights

Neither oven nor griddle will operate until and unless the fire suppression is charged and cocked, and the ventilator section is operating.

13

Image 15
Contents Important do not Discard this Manual 509509 305936 OpM WVOC-G136 Total Power CordIntroduction Model Volts WattsVentilator Section Operating Features & Controls 509 305936 OpM WVOC-G136 Ventilator Section Controls & Indicator Lights Convection Oven Section Controls Ventilator Section ControlsElectric Shock Hazard Risk DamageHOT Surface STD Ventilator Warning Indicators509 305936 OpM WVOC-G136 509 305936 OpM WVOC-G136 Fire Suppression System Installation Fire HazardAuthority Having Jurisdiction Filter Installation Slipping / Falling Hazard Spilled OIL Grease Trough and Grease CUP InstallationGriddle Installation Griddle Installation Oven Rack InstallationVentilator Operation OperationPRE-FILTER Element Product Using the GriddleGriddle Operation Preparing the Griddle SurfaceElectrical Manual Cook ModeProgram Cook Mode Convection Oven Operating InstructionsBurn Hazard Temperature Offset ModePastries Suggested Cooking TimesConvection Oven Product Temp Time Number Minutes Racks Bread ProductsConvection Oven Cleaning Instructions Cleaning InstructionsCleaning Instructions Frequency Weekly Ventilator Weekly CleaningInterior Ventilator Monthly CleaningFrequency Monthly ExteriorConvection Oven FAN will not RUN Troubleshooting SuggestionsNo Part of the Appliance will Heat Griddle will not HeatServicing Instructions Temperature CalibrationPrecautions FrequencyTools Fire Hazard Maintenance Schedules509 305936 OpM WVOC-G136 All models 286ºF Ansul Health Hazards 509 305936 OpM WVOC-G136 509 305936 OpM WVOC-G136 Wells

WVOC-G136 specifications

The Wells WVOC-G136 is a highly regarded vapor abatement system specifically designed for the treatment of volatile organic compounds (VOCs) in industrial applications. This technology showcases a series of innovative features and characteristics that make it a top choice for facilities looking to minimize their environmental footprint while ensuring compliance with increasingly stringent regulations.

One of the standout features of the WVOC-G136 is its efficient performance in removing harmful VOCs from emissions. Utilizing advanced adsorption technology, the system effectively captures and retains volatile organic compounds, significantly reducing their presence in exhaust streams. This not only helps organizations meet regulatory requirements but also aids in reducing potential health hazards associated with VOC exposure.

The WVOC-G136 employs a user-friendly design that simplifies the installation and maintenance processes. With modular components, it can be easily integrated into existing systems, offering flexibility and adaptability to various industrial settings. This design minimizes downtime and maintenance costs, making it a cost-effective solution for businesses seeking to enhance their emission control strategies.

In terms of technology, the Wells WVOC-G136 incorporates high-efficiency activated carbon media to maximize absorption rates. This media is designed to have a high surface area, allowing for the effective capture of a wide range of VOCs, including hazardous air pollutants. The system also features an advanced monitoring and control interface, which allows operators to track performance metrics continuously and ensure optimal functioning.

Another notable characteristic of the WVOC-G136 is its eco-friendly design. By reducing VOC emissions, the system contributes positively to air quality and overall environmental sustainability. This makes it ideal for industries such as pharmaceuticals, chemicals, and manufacturing, where VOCs are often prevalent.

Moreover, the WVOC-G136 is built with durability in mind, featuring robust materials and construction that can withstand the rigors of industrial environments. Its reliable operation ensures consistent performance over time, providing peace of mind for facilities focused on compliance and emission reductions.

In summary, the Wells WVOC-G136 is a powerful vapor abatement solution that combines advanced technology with user-friendly features. Its efficient VOC removal capabilities, eco-friendly design, and durable construction make it an ideal choice for industries facing stringent regulatory challenges while striving to protect the environment.