Wells WVOC-G136 operation manual Ansul

Page 30

ANSUL®

ANSUL INCORPORATED

 

 

MATERIAL SAFETY DATA SHEET

MARINETTE, WI 54143-2542

 

 

ANSULEX Low pH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QUICK IDENTIFIER (In Plant Common Name)

 

 

Manufacturer’s

ANSUL INCORPORATED

 

Emergency

CHEMTREC

 

 

Name:

 

Telephone No.:

 

 

 

 

 

(800) 424-9300 or (703) 527-3887

Address:

One Stanton Street, Marinette, WI 54143-2542

 

 

Other Information

(715) 735-7411

 

 

 

 

 

 

 

Calls:

 

 

 

 

 

 

 

 

 

Prepared By:

Safety and Health Department

 

Date Prepared:

February 1, 1999

 

 

 

 

 

 

 

 

 

 

SECTION 1 - IDENTITY

 

 

 

 

 

 

Common Name (Used on Label):

ANSULEX Low pH Liquid Fire Suppressant

 

CAS No.:

N/A

 

 

(Trade Name and Synonyms)

 

 

 

 

 

 

 

 

 

 

 

 

 

Chemical

N/A This is a Mixture

 

Chemical

Mixture

 

 

Name:

 

Family:

 

 

 

 

 

 

 

 

 

 

 

 

Formula:

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECTION 2 - INGREDIENTS

 

 

 

 

 

 

PART A - HAZARDOUS INGREDIENTS

 

 

 

 

 

 

Principal Hazardous Component(s) (chemical and common name(s)):

Wt.%

 

CAS No.

ACGIH TLV

Acute Toxicity Data

 

None

 

 

N/A

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PART B - OTHER INGREDIENTS

Other Component(s) (chemical and common name(s)):

Wt.%

CAS No.

ACGIH TLV

Acute Toxicity Data

 

 

 

 

 

Proprietary Mixture of Organic and Inorganic Salts

48.0 - 50.0

N/A

N/E

NDA

 

 

 

 

 

Phosphoric Acid

0.2

7664-38-2

N/E

NDA

 

 

 

 

 

EDTA

0.65

64--02-8

N/E

NDA

 

 

 

 

 

Yellow-Green Fluorescent Dye

0.011

518-47-8

N/E

Oral LD50(rat)

 

 

 

 

6800 mg/kg

Water

Approx. 50.0

7732-18-5

N/E

NDA

 

 

 

 

 

SECTION 3 - PHYSICAL AND CHEMICAL CHARACTERISTICS (Fire and Explosion Data)

Boiling

113ºC

 

 

 

 

Specific

1.33

Vapor Pressure

Not Determined

Point:

 

 

 

 

Gravity (H2O=1):

(mm Hg):

 

 

 

 

 

 

 

Percent Volatile

Approx. 50.0

Vapor Density:

1.03

Evaporation Rate: Approx. 0.005

 

 

by Volume (%):

 

 

(Air = 1):

 

 

(Butyl Acetate=1):

 

 

 

Solubility

100%

 

 

 

 

Reactivity in

Mild exothermic reaction

 

 

in Water:

 

 

 

 

Water:

 

 

Appearance

Fluorescent Yellow Colored Liquid, Mild Odor

 

 

 

 

and Odor:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flash Point:

None to boiling

Flammable Limits

 

N/A

Extinguisher

N/A

Auto-Ignition

N/A

 

in Air % by Volume:

Media:

Temperature:

Special Fire

 

 

 

 

 

 

 

 

 

Fighting Procedures: NONE - THIS IS AN EXTINGUISHING AGENT

 

 

 

 

Unusual Fire and

None

 

 

 

 

 

 

 

 

Explosion Hazards:

 

 

 

 

 

 

 

 

SECTION 4 - PHYSICAL HAZARDS

 

 

 

 

 

 

Stability:

Unstable

 

Conditions

 

N/A

 

 

 

 

 

Stable

 

to Avoid:

 

 

 

 

 

 

 

 

 

 

 

 

 

Incompatibility

 

Reactive Metals, ClF3, electrically energized equipment, any material reactive with water.

 

(Materials to Avoid):

 

 

 

 

 

 

 

 

 

 

 

 

Hazardous

 

Not established, acrid fumes.

 

 

 

 

 

Decomposition Products:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hazardous

May Occur

 

Conditions

 

N/A

 

 

 

 

Polymerization:

Will Not Occur

 

to Avoid:

 

 

 

 

 

509 305936 OpM WVOC-G136

28

Image 30
Contents 509 Important do not Discard this Manual509 305936 OpM WVOC-G136 Model Volts Watts Power CordIntroduction TotalVentilator Section Operating Features & Controls 509 305936 OpM WVOC-G136 Ventilator Section Controls & Indicator Lights Ventilator Section Controls Convection Oven Section ControlsElectric Shock Hazard Risk DamageHOT Surface Ventilator Warning Indicators STD509 305936 OpM WVOC-G136 509 305936 OpM WVOC-G136 Fire Suppression System Installation Fire HazardAuthority Having Jurisdiction Filter Installation Griddle Installation Oven Rack Installation Grease Trough and Grease CUP InstallationGriddle Installation Slipping / Falling Hazard Spilled OILVentilator Operation OperationPRE-FILTER Element Preparing the Griddle Surface Using the GriddleGriddle Operation ProductConvection Oven Operating Instructions Manual Cook ModeProgram Cook Mode ElectricalTemperature Offset Mode Burn HazardBread Products Suggested Cooking TimesConvection Oven Product Temp Time Number Minutes Racks PastriesCleaning Instructions Convection Oven Cleaning InstructionsCleaning Instructions Ventilator Weekly Cleaning Frequency WeeklyExterior Ventilator Monthly CleaningFrequency Monthly InteriorGriddle will not Heat Troubleshooting SuggestionsNo Part of the Appliance will Heat Convection Oven FAN will not RUNTemperature Calibration Servicing InstructionsPrecautions FrequencyTools Maintenance Schedules Fire Hazard509 305936 OpM WVOC-G136 All models 286ºF Ansul Health Hazards 509 305936 OpM WVOC-G136 509 305936 OpM WVOC-G136 Wells

WVOC-G136 specifications

The Wells WVOC-G136 is a highly regarded vapor abatement system specifically designed for the treatment of volatile organic compounds (VOCs) in industrial applications. This technology showcases a series of innovative features and characteristics that make it a top choice for facilities looking to minimize their environmental footprint while ensuring compliance with increasingly stringent regulations.

One of the standout features of the WVOC-G136 is its efficient performance in removing harmful VOCs from emissions. Utilizing advanced adsorption technology, the system effectively captures and retains volatile organic compounds, significantly reducing their presence in exhaust streams. This not only helps organizations meet regulatory requirements but also aids in reducing potential health hazards associated with VOC exposure.

The WVOC-G136 employs a user-friendly design that simplifies the installation and maintenance processes. With modular components, it can be easily integrated into existing systems, offering flexibility and adaptability to various industrial settings. This design minimizes downtime and maintenance costs, making it a cost-effective solution for businesses seeking to enhance their emission control strategies.

In terms of technology, the Wells WVOC-G136 incorporates high-efficiency activated carbon media to maximize absorption rates. This media is designed to have a high surface area, allowing for the effective capture of a wide range of VOCs, including hazardous air pollutants. The system also features an advanced monitoring and control interface, which allows operators to track performance metrics continuously and ensure optimal functioning.

Another notable characteristic of the WVOC-G136 is its eco-friendly design. By reducing VOC emissions, the system contributes positively to air quality and overall environmental sustainability. This makes it ideal for industries such as pharmaceuticals, chemicals, and manufacturing, where VOCs are often prevalent.

Moreover, the WVOC-G136 is built with durability in mind, featuring robust materials and construction that can withstand the rigors of industrial environments. Its reliable operation ensures consistent performance over time, providing peace of mind for facilities focused on compliance and emission reductions.

In summary, the Wells WVOC-G136 is a powerful vapor abatement solution that combines advanced technology with user-friendly features. Its efficient VOC removal capabilities, eco-friendly design, and durable construction make it an ideal choice for industries facing stringent regulatory challenges while striving to protect the environment.