PROGRAMMING
Table 4-2 Key and Display Assign Screen Description
KEY ASSIGN PARAMETERS
The and
Parameter | Key |
|
|
| Description |
|
Label |
|
|
|
| ||
|
|
|
|
|
|
|
Null | No function (key disabled). |
| ||||
CH Up | CH UP | Scroll up or down through the programmed channels. Holding the key down causes the function to | ||||
CH Down | CH DN | repeat. |
| |||
|
|
|
|
|
|
|
CH 1 | Directly selects Channels 1, 2, 3, or 4, respectively. |
| ||||
CH 2 |
|
|
|
|
| |
CH 3 |
|
|
|
|
| |
CH 4 |
|
|
|
|
| |
|
|
|
|
|
| |
Bank | BANK | Toggles the current bank between Bank 1 and Bank 2. This key can be programmed only if the “MR- | ||||
|
| CH Bank/Free” parameter in this screen is programmed “Bank”. |
| |||
|
|
|
|
|
| |
Scan A | SCAN | Pressing this key toggles scanning on and off. In addition, pressing and holding the key enables the | ||||
Scan B |
| scan list select mode. The current scan list is indicated, and it is changed by pressing the up/down | ||||
Start/Stop |
|
|
|
| keys. Either the Scan A or Scan B mode or both can be programmed. Operation is as follows: | |
|
|
|
| |||
|
|
|
| |||
|
|
|
|
| Scan A |
|
|
| |||||
|
| mitter is keyed during scanning, the scan mode is exited. |
| |||
|
| |||||
|
| the transmitter is keyed during scanning, scan automatically resumes when the Auto Reset Timer | ||||
|
| expires. |
| |||
|
|
|
|
| Scan B |
|
|
| |||||
|
| keyed during scanning, scan automatically resumes when the Auto Reset Timer expires. | ||||
|
|
|
|
|
| |
Scan Add/ | TAG | Scan list programming key. Pressing this key changes the scan list status of the current channel in the | ||||
Delete |
| current scan list (see Section 3.6.2). |
| |||
|
|
|
|
|
| |
Prio A | PRI A | Pressing a Prio A key selects the Priority A channel, and pressing a Prio B key selects the Priority B | ||||
Prio A (Re) | PRI A | channel. Pressing a Prio A (Rewrite) key also selects the Priority A channel. In addition, if it is held, the | ||||
Prio B | PRI B | current channel is made the Priority A channel. Priority channel sampling is programmed in the Scan | ||||
|
| List screen (see Table |
| |||
|
|
|
|
|
| |
Moni | MONI | Toggles the monitor mode on and off. This mode deactivates the Call Guard (CTCSS/DTCSS) or | ||||
(Audi) |
| |||||
|
| long as it is held. |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| November 1998 |
|
| Part No. |