Omega Engineering CCT-55-I CCT-55-V DC Voltage Integrator Electrical Features, Input, Output

Page 10

CCT-55-V; DC VOLTAGE INTEGRATOR

ELECTRICAL FEATURES

INPUT

Table 4 indicates all the standard available ranges for the CCT-55-V and its electrical specifications. The position of the jumpers are indicated in Fig. 8.

For different signal ranges, contact the engineering department for more information.

Reference

A

B

C

D

E

 

 

 

 

 

 

Range

0 to 100 mV

0 to 1 V

0 to 10 V

0 to 100 V

0 to 650 V

 

 

 

 

 

 

Min. input span *

10 mV

0.1 V

1 V

10 V

100 V

 

 

 

 

 

 

Impedance

100 K

100 K

 

1 M

 

 

 

 

 

 

 

Overvoltage

25 V

75 V

 

1,000 V

 

 

 

 

 

 

 

* The minimum input span is the minimum difference between the maximum and minimum

input for a full scale output.

 

TABLE 4

 

 

OUTPUT

 

 

FREQUENCY : Pulses per second

0 to 10,000 (12 selectable ranges)

Pulses per hour

0 to 8,790 (13 selectable ranges)

TYPE OF PULSES : Voltage

24 Vdc @ 20 mA maximum

Sink Current

100 mA. (24 Vdc external power supply)

PULSE WIDTH

100 ms; 50 % of the full cycle or

 

variable with frequency ratio

ACCURACY

0.2 % FS

RESPONSE TIME

250 ms

GALVANIC ISOLATION

Input, Output and Power Supply are all isolated

 

to 2 kVeff. 50 Hz/1 m.

GENERAL SPECIFICATIONS

 

 

STORAGE TEMPERATURE

-30° to +80°C

OPERATING TEMPERATURE

-10° to +60°C

TEMPERATURE COEFFICIENT

0.015 %/°C

STANDARD POWER SUPPLY

115 Vac (±10%) 50/60 Hz

POWER CONSUMPTION

1.5 VA

TEST VOLTAGE

4 kVeff. 50 Hz/1m.

9

Image 10
Contents User’sGuide Omega.comTM Table of Contents Procedure for Disassembly Open the HousingProcedure Internal OverviewPower Supply module MA Changing the Power SupplyOverview Types of Pulses Frequency Output Range Selection Pulses PER SecondPulses PER Hour Pulses / Hour Close Jumpers Pulse Width Solder PadsOffset Adjust Amplifier GainInput CCT-55-V DC Voltage Integrator Electrical FeaturesGeneral Specifications OutputAdjustment and Calibration Procedure Signal Input Range SelectionRange Selection CCT-55-I DC Current Integrator Electrical Features Signal InputInput Wiring Connections CCT-55-VDimensions Mechanical SpecificationsTechnical Data Page USAWARRANTY/DISCLAIMER Temperature