CCT-55-I : DC CURRENT INTEGRATOR
ELECTRICAL FEATURES
SIGNAL INPUT
Table 6 indicates two standard available ranges for the
For other signal ranges, contact the engineering department for more information.
Reference | A | B |
Input range | 0 to 5 mAdc | 0 to 50 mAdc |
Min. input Span * | 0.5 mAdc | 5 mAdc |
|
|
|
Impedance | 20 Ω | 20 Ω |
TABLE 6
*The minimum input span is the minimum difference between the maximum and minimum input for a full scale output.
Overload100 mAdc 100 mAdc
OUTPUT
FREQUENCY : Pulses per second | 0 to 10,000 (12 selectable ranges). | |
Pulses per hour | 0 to 8,790 (13 selectable ranges). | |
TYPE OF PULSES: Voltage | 24 Vdc @ 20 mA maximum. | |
Sink Current | 100 mA. (24 Vdc external power supply) | |
PULSE WIDTH | 100 mS; 50 % of the full cycle or | |
| variable with frequency ratio. | |
ACCURACY | ≤ | 0.2 % FS. |
RESPONSE TIME | ≤ | 250 ms. |
GALVANIC ISOLATION | Input, Output and Power Supply are all isolated | |
| to 2 kVeff. 50 Hz/1 m. | |
GENERAL SPECIFICATIONS |
|
|
STORAGE TEMPERATURE | ||
OPERATING TEMPERATURE | ||
TEMPERATURE COEFFICIENT | ≤ | 0.015 %/°C. |
STANDARD POWER SUPPLY | 115 Vac (±10%) 50/60 Hz. | |
POWER CONSUMPTION | ≤ | 1.5 VA. |
TEST VOLTAGE | 4 kVeff. 50 Hz/1m. |