Verify that component box and contactor box components (i.e. computer/controller, relays, interface boards, transformers, contactors, etc.) are in good condition and free from oil and other debris.

Verify that component box and contactor box wiring connections are tight and that wiring is in good condition.

Verify that all safety features (i.e. contactor shields, drain safety switches, reset switches, etc.) are present and functioning properly.

Verify that the frypot is in good condition and free of leaks and that the frypot insulation is in serviceable condition.

Verify that all wiring harnesses and connections are tight and in good condition.

Built-In Filtration System

Inspect all oil-return and drain lines for leaks and verify that all connections are tight.

Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the crumb basket, advise the owner/operator that the crumb basket should be emptied into a fireproof container and cleaned daily.

Verify that all O-rings and seals are present and in good condition. Replace O-rings and seals if worn or damaged.

Check filtration system integrity as follows:

With the filter pan empty, place each oil return handle, one at a time, in the ON position. Verify that the pump activates and that bubbles appear in the cooking oil.

Close all oil return valves (i.e., place all oil return handles in the OFF position). Verify proper functioning of each oil return valve by activating the filter pump using the lever on one of the oil return handle microswitches. No air bubbles should be visible in any frypot.

Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to 335°F (168°C) into the filter pan and close the frypot drain valve. Place the oil return handle in the ON position. Allow all cooking oil to return to the frypot, indicated by bubbles in the cooking oil. Return the oil return handle to the OFF position. The frypot should have refilled in no more than 2 minutes and 30 seconds.

5-3

Image 23
Contents 8196151 Canada Page Warranty Statement Parts Return This page Intentionally Left Blank General Safety InformationDefinitions Computer Information for the M2000 ComputersEuropean Community CE Specific Information What to do if your equipment arrives damaged Shipping Damage Claim ProcedureService Information General Installation Requirements Page Power Requirements Page BIRE14/MRE14 Series E4 Electric Fryer Operating Instructions Operation Equipment Setup and Shutdown ProceduresIntroduction Do not USE Filter Powder with the PAD Turn the filter handle to the on position Page Clean Behind Fryers Weekly Fryer Clean Detachable Parts and Accessories WeeklyAnnual/Periodic System Inspection Built-In Filtration System Introduction Troubleshooting Computer and Heating Problems Problem Probable Causes Corrective ActionCorrective Action D. If the circuitry in the fryer ProblemCelsius Error Messages and Display ProblemsFailure Shows HI 2 BADFailure with Start Filtration ProblemsProblem This page Intentionally Left Blank Service Hotline