Frymaster BIRE14, MRE14 warranty Error Messages and Display Problems, Celsius

Page 27

6.2.2 Error Messages and Display Problems

Problem

Probable Causes

Corrective Action

M2000 display is in

 

M2000 computers may be

 

programmed to display in either

wrong temperature

Incorrect display option

Fahrenheit or Celsius. Refer to the

scale (Fahrenheit or

programmed.

separate M2000 Computer Operation

Celsius).

 

Manual for instructions on changing

 

 

the display.

 

 

This display will appear only if the

 

 

fryer is in the non-dedicatedmode

M2000 display

 

and the frypot temperature rises 15°

Fryer is 15ºF (8ºC) above setpoint.

(8°C) or more above the

shows HI.

programmed setpoint. This indicates

 

 

a problem with the temperature

 

 

control circuitry. Turn the fryer off

 

 

and call FASC.

 

 

This in an indication of a

M2000 display

Frypot temperature is more than

malfunction in the temperature

control circuitry, including a failure

410ºF (210ºC) or, in CE countries,

shows HOT.

of the high-limit thermostat. Shut

 

395ºF (202ºC).

the fryer down immediately and call

 

 

 

 

FASC.

 

 

This display is normal when the

 

 

fryer is first turned on and may

M2000 display

Frypot temperature is between

appear for a short while if a large

batch of frozen product is added to

shows LOW TEMP.

180°F (82°C) and 315°F (157°C).

the frypot. If the display never goes

 

 

 

 

out, the fryer is not heating. Shut the

 

 

fryer down and call FASC.

M2000 display

 

This indicates a problem within the

Problem with the temperature

temperature measuring circuitry that

shows PROBE

measuring circuitry including the

is beyond the scope of operator

FAILURE.

probe.

troubleshooting. Shut the fryer

 

 

down and call FASC.

 

 

This indicates that the fryer is not

 

 

heating. It is displayed if the fryer

 

 

loses its ability to heat oil. It is also

M2000 display

Open drain valve, failed computer,

displayed when the oil temperature is

above 450°F (232°C) and the high-

shows IGNITION

failed interface board, open high-

limit thermostat has opened, halting

FAILURE.

limit thermostat.

the heating of the oil. Verify that the

 

 

 

 

drain valves are fully closed. If this

 

 

does not correct the problem, call

 

 

your FASC.

M2000 display

 

This is displayed only during a test

Computer in high-limit test mode.

of the high-limit circuit and indicates

shows HI-LIMIT.

that the high-limit has opened

 

 

properly.

6-4

Image 27
Contents 8196151 Canada Page Warranty Statement Parts Return This page Intentionally Left Blank General Safety InformationComputer Information for the M2000 Computers European Community CE Specific InformationDefinitions What to do if your equipment arrives damaged Shipping Damage Claim ProcedureService Information General Installation Requirements Page Power Requirements Page BIRE14/MRE14 Series E4 Electric Fryer Operating Instructions Operation Equipment Setup and Shutdown ProceduresIntroduction Do not USE Filter Powder with the PAD Turn the filter handle to the on position Page Clean Behind Fryers Weekly Clean Detachable Parts and Accessories Weekly Annual/Periodic System InspectionFryer Built-In Filtration System Introduction Troubleshooting Computer and Heating Problems Problem Probable Causes Corrective ActionCorrective Action D. If the circuitry in the fryer ProblemCelsius Error Messages and Display ProblemsShows HI 2 BAD Failure withFailure Start Filtration ProblemsProblem This page Intentionally Left Blank Service Hotline