Frymaster 2836 manual Replace Transformer, Replace Temperature Probe

Page 8

4.Ensure that wire harnesses are connected to back of interface board prior to securing interface board. Also, ensure that wiring and wire harnesses are connected to the proper terminals.

1.4 Replace Transformer

1.Unplug all power cords. Perform Procedure 1.2, Steps 1-4, Replace Computer/Controller.

2.Hold new transformer up to old transformer to be replaced and disconnect one wire at a time from old and connect to new.

3.Remove the screws that secure the transformer to the component box.

4.Install the new transformer by reversing the preceding procedures. Make sure you reconnect the wiring to the proper terminals and the harnesses to the correct connectors.

1.5 Replace Temperature Probe

1. Unplug fryer from the electrical source.

2. Drain the cooking oil from the

.

3.Remove the fryer from the exhaust hood to gain access to the rear of the fryer.

4.If unit is equipped with modular basket lift, remove basket lift assembly and set aside.

5.Remove the screws from the top cap and back cover(s). Set the cover(s), top cap and screws aside.

6.Disconnect the wire harness containing the probe wiring. It may be necessary to remove the wire ties.

7.Use a pin-pusher (P/N 806-4855 or P/N 807- 0928) to remove the red and white probe wires from the connector. Note probe pin location in plug. Pull the probe wires out of the insulation.

8.Remove the screw(s) securing the probe bracket to the element. Remove the metal wraps securing the probe to the element.

Use a pin-pusher to remove probe wires from

connector (arrows).

1-3

Image 8
Contents Series Electric Fryers Service and Parts Manual Hour Service HotlineCanada Page Table of Contents Parts List Component Box Contactor BoxReplace Interface Board GeneralReplace Computer/Controller Replace Temperature Probe Replace TransformerReplace Heating Element Replacement element. Ensure the pin Replace High-Limit Replace FrypotBuilt-in Filter System Service Procedures Replace Contactor Latching or HeatingSediment Particle Oil Flow Up for reverse Down for forward Basket Lift Service Procedures Simplified Schematic BINDING/JAMMING Problems Electric Interface Board Diagnostic Chart Diagnostic LED LegendProbe Resistance Chart Probe Resistance ChartWiring Diagrams, Main 208/240V Wiring Diagrams, Main 480V 120 V Controls Wiring Diagrams, Main FP28DV/36 480V 120 V Controls Wiring Diagrams, Modular Basket Lifts Wiring Diagrams 208/240V Systems With Built-in Filtration Wiring Diagrams 480V Systems With Built-in Filtration Series Electric Fryers Parts List AccessoriesBasket Lift Assembly Modular and Related Components Basket Lift Assembly Modular and Related Components Basket Lift Assembly Modular and Related Components Page 1.1 FP228 Cabinet and Related Components 1.2 FP128/136 Cabinet and Related Components 1.2 FP128/136 Cabinet and Related Components 1.3 FP128/236 Cabinet and Related Components Cabinet Assembly FP128/236 use 106-5891 for FP128DV/236S Door Components Dump Station Components Computer and Related Components Contactor and Power Cord Box Assembly Part Number Terminal Block Mount Assembly Component Box Assembly Component Box Assembly Filter Pan and Related Components Built-in Filtration Handle, Drain Valve Use 230-0892 for FP14 FP28DV Drain Components Elements and Related Components References Previous models Oil Disposal Wand Oil Return Assembly Return Assembly Filter Pump Assembly Wiring Harnesses and Cables Part Number Description Basket Lift HarnessesThis page Intentionally Left Blank Service Hotline