Fig. 7: Two screws (see arrows) at the base of each side of the cabinet secure the sides.

Cabinet Service Procedures

3.HHHH means RTD indicates the temperature is above 255°F (124°C), but below "Open" circuit resistance, which causes SENS ALARM.

4.UHC VERSION _ _ _ (version number will vary)

appears for five seconds when the unit is turned on.

5.The cabinet also displays a variety of error messages, which are shown on page 3-1.

2.6Removing/Replacing Bezels

1.Remove power from unit.

2.Remove screws at the base of each side and remove side panels. (See figure 7.)

3.Unplug the bezel from the distribution board.

4. Plug the replacement bezel into the distribution board, return power to the unit and test the bezel/cabinet for accurate operation.

5.Remove replacement bezel and remove power from the unit.

6.Loosen the hex nut which secures the row and remove the allen screw, which holds the bezel. Also remove, if present, the small bezel-securing screw. (See photo below.)

7.Push, if necessary, on the mounted bezel through the access port in the inner panel to loosen the bezel. (See Figure 8 below.)

8.Remove bezel; clean and degrease the groove in the heater plate.

9.Route ribbon cable for the new bezel through the inner panel of the cabinet and press the new bezel into place. Ensure it is firmly seated and tighten hex nuts and replace allen screws.

10.Return sides and reposition cabinet for operation.

Fig. 8: Loosen the hex bolt and remove the allen screw (arrows, upper photo). Some row positions may have an additional screw securing the bezel to the cabinet (lower photo). Push through the access port (arrow, upper photo), if necessary, to remove the bezel from the cabinet .

2-9

Image 14
Contents 8196606* 24-Hour Service Hotline UHCPage Table of Contents Functional Description Theory of OperationStart Up Indicators and Test Points Cabinet Service Procedures Updating Software/Capturing ConfigurationsCopy from UHC to USB Adjusting Display Brightness Placing the cabinet in Service ModeSwitching Heater Plates Off Individually Readdressing the Cabinet Accessing the Electronic Components Circuit Board LED DiagnosticsDistribution Boards Tests Power Supply2 RTD Heater Plate DisplayShorted Triac Display MeaningsRemoving/Replacing Bezels Removing a Row Replace Heater Plate/RTDHeater plate slides from the insulation Cabinet Troubleshooting Symptom Possible Causes Tests Parts Lists, Exploded Views Cabinet PartsComponent Shelf Part Number Wiring Diagram, Delta Power, L1-L2 UHC-HD, WYE Power, L1-N Service Hotline