Frymaster 8196606 Placing the cabinet in Service Mode, Switching Heater Plates Off Individually

Page 9

Cabinet Service Procedures

2.2 Placing the cabinet in Service Mode

The cabinet can be put in service mode, a diagnostic settings which allows the heater plates to be controlled individually, brightness settings on the displays adjusted and re-addressing for unique arrangements of bezels. Follow the steps below :

Switching Heater Plates Off Individually

When troubleshooting, it may be useful to switch heater plates off individually. Follow the instructions below:

1.Press the programming key.

2.Enter 1111 at the Enter Access Sequence prompt.

3.The screen will scroll Row 1 Top Heater Off; pressing OK turns it back on.

4.Voltage can be measured between the plate-specific heater leads on the distribution board and the common block to the right of the distribution board as the heater plates are switched, individually, on and off.

5.Scroll to other plates with WX.

6.Ensure the plates are on before backing out of the Service Mode with the /.

Adjusting Display Brightness

When multiple row positions are timing the same item, the display with the least remaining time is the brightest. All others are dimmer as are positions not actively timing a product. The relative brightness of the bright display and the dim display can be adjusted. Follow the instructions below:

1.Press the programming key.

2.Enter 1111 at the Enter Access Sequence prompt.

3.Press OK.

4.The screen will scroll Row 1 Top Heater Off.

5.Scroll with X through all the Heater Plate prompts until the screen displays Press OK to Adjust Bright Row Display.

6.Press OK.

7.The cabinet’s row displays become

Decrease

Increase

88888 20

8.Press the timer button next to the Decrease display to lessen the brightness; the number displayed at the right will decrease. Press the timer button next to the Increase display to increase the brightness; 20 is the maximum.

9.Press OK. The display becomes Adjust Dim Intensity. The cabinet’s row displays become

Decrease

Increase

88888 03

10.Press the timer button next to the Decrease display to lessen the brightness; the number displayed at the right will decrease. Press the timer button next to the Increase display to increase the brightness; 1 is the minimum.

11.Press OK.

12.Cabinet returns to menu display.

2-4

Image 9
Contents UHC 8196606* 24-Hour Service HotlinePage Table of Contents Theory of Operation Functional DescriptionStart Up Indicators and Test Points Updating Software/Capturing Configurations Cabinet Service ProceduresCopy from UHC to USB Placing the cabinet in Service Mode Switching Heater Plates Off IndividuallyAdjusting Display Brightness Readdressing the Cabinet Circuit Board LED Diagnostics Accessing the Electronic ComponentsTests Power Supply 2 RTDDistribution Boards Shorted Triac DisplayHeater Plate Display MeaningsRemoving/Replacing Bezels Replace Heater Plate/RTD Removing a RowHeater plate slides from the insulation Cabinet Troubleshooting Symptom Possible Causes Tests Cabinet Parts Parts Lists, Exploded ViewsComponent Shelf Part Number Wiring Diagram, Delta Power, L1-L2 UHC-HD, WYE Power, L1-N Service Hotline