Kramer Electronics VP-411DS user manual Flash Memory Upgrade

Page 16

Flash Memory Upgrade

2.Under the “Step 1 ± Communications” area, set the definitions on the screen as follows:

￿COM Port: select the active COM port on your computer

￿Baud Rate: 19200

￿Device: LPC2368

￿Interface: None (ISP)

￿Oscillator Freq. (MHz): 12.000

3.Under the “Step 2 ± Erase” area, check the “Erase all Flash+Code Rd Prot” box.

4.Under the “Step 3 ± Hex File” area select the hex file. For example, select VP-411DS_12.hex”.

5.Under the “Step 4 ± Options” area, check the “Verify after programming” box.

6.In order to verify communication, select "Read device signature" from the ISP menu. You should get a response as the example below:

7.Under the “Step 5 ± Start!” area, press the start button and wait for the completion of the process.

8.Close the “Flash Magic” window.

9.Turn the power OFF on the VP-411DSunit.

10.Disconnect the RS-232rear panel port on the VP-411DSunit from the Null-modem adapter.

11.On the underside panel, slide the switch to NORMAL.

12.Turn the power ON on the VP-411DSunit.

14

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Image 16
Contents Model Contents TablesGetting Started IntroductionQuick Start Getting Started Overview For example model number AD2512C, part number Your VP-411DS 4x1 Automatic Uxga / Audio Switcher Feature FunctionUsing the IR Transmitter Define the underside of the VP-411DSUsing the VP-411DS 4x1 Automatic Uxga / Audio Switcher Connecting the VP-411DS 4x1 Automatic Uxga / Audio SwitcherVP-411DS 4x1 Automatic Uxga / Audio Switcher Connections Setting the Priority Dipswitches VP-411DS Dipswitches Dipswitch Priority SetupConnecting the Remote Connector Connecting the Contact Closure Remote Control PINsConnecting a PC Connecting the PCConnecting the PC to the RS-232 Port Flash Memory UpgradeDownloading from the Internet Upgrading Firmware Flash Magic ScreenFlash Memory Upgrade Technical Specifications Table of Hex Codes for Serial CommunicationKramer Protocol Protocol DefinitionsInstruction Codes for Protocol 81 i.e dec+ 3dec for 2nd byte, 128dec+ 5dec for 3rd byte Limited Warranty 2900-000377 REV