Bloomfield WVG-136RWT operation manual Item Description, Change Display Mode ºF or ºC

Page 18

OPERATION (continued)

DRAWER WARMER OPERATION (when provided)

1

2

3

 

 

ºF

 

 

ºC

 

 

LOAD

PROCESS

 

 

4

 

5

 

 

ºF

 

 

ºC

LOAD

PROCESS

ºF

ºC

LOAD

PROCESS

HOLD

10 SEC.

ITEM DESCRIPTION

1PROCESS Key:

Press to view actual temperature of cavity.

24 Character LED Display:

Normally shows SETPOINT temperature. ºF or ºC Indicator:

3Glows to indicate if unit is configured for degrees Fahrenheit or degrees Celsius.

4LOAD Indicator:

Glows when heating element is energized. Increment and Decrement Keys:

5Press UP arrow to increase Press DOWN arrow to decrease

RWT- CONTROL MODULE

SET SETPOINT TEMPERATURE

Press an arrow key:

UP arrow to increase DOWN arrow to decrease

Release key when desired setpoint temperature is displayed.

Reading is locked into memory 3 seconds after last key stroke.

Minimum setpoint is 140ºF (60ºC)

Maximum setpoint is 250ºF (121ºC)

CHANGE DISPLAY MODE ( ºF or ºC)

Press and hold UP arrow and DOWN arrow keys for 10 seconds.

Release keys when display reads F C.

Within 3 seconds, press UP arrow or DOWN arrow key until desired indicator (ºF or ºC) glows.

The new value will lock into memory 3 seconds after last keystroke.

502 p/n 304986 OpM WVG-136 Ventless Griddle

16

Image 18
Contents 502 Important do not Discard this Manual502 p/n 304986 OpM WVG-136 Ventless Griddle Introduction Back Side Bottom TOPVentilator Section Operating Features & Controls 502 p/n 304986 OpM WVG-136 Ventless Griddle Ventilator Section Controls & Indicator Lights Ventilator Section Controls Optional Warmer Section ControlsElectric Shock Hazard Risk DamageHOT Surface Ventilator Indicators STD502 p/n 304986 OpM WVG-136 Ventless Griddle 502 p/n 304986 OpM WVG-136 Ventless Griddle Fire Suppression System Installation Fire HazardAuthority Having Jurisdiction Filter Installation Roll Warmer Installation Grease Trough and Grease CUP InstallationGriddle Installation Slip / Fall Hazard Spilled OILVentilator Operation PRE-FILTER ElementGriddle Operation Recommended Grilling Times and TemperaturesTemperature ºF Seasoning Standard GriddlesOperating Chart for Drawer Warmers Heating OptionsChange Display Mode ºF or ºC Item DescriptionGriddle Daily Cleaning Never USE Steel Wool to Clean the Griddle SurfaceFrequency Daily Ventilator Weekly Cleaning Frequency WeeklyVentilator Monthly Cleaning Frequency MonthlyInterior Cleaning Instructions Maintenance Schedules Wells BLOOMFIELD,LLC Wells BLOOMFIELD,LLC Ansul Health Hazards 502 p/n 304986 OpM WVG-136 Ventless Griddle Wells Bloomfield, LLC Genuin e Parts

WVG-136RW, WVG-136, WVG-136RWT specifications

The Bloomfield WVG-136 is a high-performance coffee brewer that distinguishes itself in the competitive coffee equipment market. Designed with the professional barista in mind, the WVG-136 series, including the WVG-136RWT and WVG-136RW models, showcases a number of advanced features and technologies that ensure consistent brewing quality and user-friendly operation.

One of the standout characteristics of the WVG-136 series is its programmable functionality. Users can easily set brew times and temperatures to achieve optimal extraction, allowing for a wide range of coffee flavors and styles. The machines are equipped with an intuitive LCD control panel that simplifies programming, making it accessible even for novice operators.

The WVG-136 models are built with commercial-grade construction, featuring a durable stainless steel body that can withstand the rigors of a busy café environment. This robust design not only enhances the aesthetics of the machine but also ensures longevity, making it a wise investment for any coffee business.

In terms of technological advancement, the WVG-136 series incorporates a state-of-the-art heat exchange system. This feature guarantees rapid heating and cool-down times, enabling efficient brewing cycles without compromising on quality. Additionally, the machines utilize precision brewing technology, allowing baristas to create a wide variety of coffee profiles with minimal variations.

Another significant feature of the WVG-136 is its advanced water filtration system. The built-in water filter ensures that only the best quality water comes into contact with the coffee grounds, reducing impurities that could affect taste. This focus on water quality is essential for maximizing flavor extraction and maintaining consistent brew quality across multiple batches.

Moreover, the WVG-136RWT model includes a unique rotating spray head, which enhances the brewing process by ensuring that water evenly saturates coffee grounds. This results in a more uniform extraction, unlocking the full flavor potential of the beans.

For environments that require additional versatility, the WVG-136RW model offers dual functionality, supporting both pour-over and direct-connect operations. This capability makes it an ideal choice for locations that serve a high volume of customers while requiring flexibility in brewing options.

In conclusion, the Bloomfield WVG-136, WVG-136RWT, and WVG-136RW coffee brewers represent a significant advancement in commercial brewing technology. Their combination of programmable features, robust construction, precision brewing capabilities, and advanced water filtration systems make them ideal for coffee enthusiasts and professional baristas alike. Investing in any of these models is a step towards achieving exceptional coffee quality and operational efficiency in any coffee service environment.