SERVICING INSTRUCTIONS
CAUTION:
SHOCK HAZARD
Opening access panels or removing warmer plates on this brew may expose uninsulated electrical components. Disconnect brewer from electrical power before removing any panel or warmer plate.
ACCESS PANELS
TOP PANEL:
Remove top panel to access hot water tank, thermo probe, heating elements, brew circuit tubing, faucet valve and piping.
Top panel is held by two screws at the rear and a retaining lip at the front.
FRONT PANEL:
Remove front panel to access controller, terminal block and solenoid.
Front panel is held by two screws at the bottom and a retaining lip at the top.
SOLENOID DOOR:
Remove solenoid door to access solenoid plumbing connections. Solenoid door is held by two screws and a retaining lip.
645 75908 Owners Manual E.B.C. Dual Airpot/Thermal Brewer
Fig. 12 Access Panels
14