Bloomfield 1090, 1091, 1092, 1093 Leveling the Unit, PLUMBER’S Installation Instructions

Page 6

INSTALLATION INSTRUCTIONS

READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION

IMPORTANT:

To enable the installer to make a quality installation and to minimize installation time, the following suggestions and tests should be done before the actual unit installation is started:

CAUTION:

EQUIPMENT DAMAGE

DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed.

CAUTION:

UNSTABLE

EQUIPMENT HAZARD

It is very important for safety and for proper operation that the brewer is level and stable when standing in its final operating position. Provided adjustable, non-skid legs must be installed at each corner of the unit. Failure to do so will result in movement of the brewer which can cause personal Injury and/ or damage to brewer.

NOTE: Water supply inlet line must meet certain minimum criteria to insure successful operation of the brewer. Bloomfield recommends 1/4" copper tubing for installation of less than 25 feet and 3/8" for more than 25 feet from a 1/2" water supply line.

Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit.

Verify that the Spray Head Gasket and Spray Disk are properly installed.

LEVELING THE UNIT

Verify that an adjustable leg is installed at each corner of the brewer, and that a rubber foot is installed on each leg.

Set Brewer in its operating location. Level the Brewer. A spirit level should be placed on the top of the unit, at the edge, as a guide when making level adjustments.

Level the unit from left to right and front to back by turning the adjustable feet. Be sure all four feet touch the counter to prevent tipping.

PLUMBER’S INSTALLATION INSTRUCTIONS

Brewer should be connected to a POTABLE WATER, COLD WATER line. Flush water line before connecting to Brewer.

DO NOT use a saddle valve with a self-piercing tap for the water line connection. Such a tap can become restricted by waterline debris. For systems that must use a saddle tap, shut off the main water supply and drill a 3/16” (minimum) tap for the saddle connection, in order to insure an ample water supply. Remember to flush the line prior to installing the saddle.

The brewer must be installed on a water line with average pressure between 20 PSI and 90 PSI. If your water pressure exceeds 90 PSI at anytime, a pressure regulator must be installed in the water supply line to limit the pressure to not more than 90 PSI in order to avoid damage to lines and solenoid.

Plumber must provide two 1/4” female flare water supplies for this brewer.

A water shut-off valve should be installed on the incoming water line in a convenient location (Use a low restriction type valve, such as a 1/4-turn ball valve, to avoid loss of water flow thru the valve.

645 75908 Owners Manual E.B.C. Dual Airpot/Thermal Brewer

4

Image 6
Contents Electronic Brew Control Warranty Statement Table of Contents ApplicabilityFeatures and Operating Controls Features & Operating ControlsPrecautions and General Information Agency Listing InformationInstallation Instructions PLUMBER’S Installation InstructionsLeveling the Unit Installation Instructions ELECTRICIAN’S Installation InstructionsOperation START-UPWater Heater Electronic Features Energizing the BrewerPage Brewing Coffee PreparationPOUR-OVER Operation Procedure Clean Coffee Brewer Cleaning InstructionsTroubleshooting Suggestions Symptom Possible Cause Suggested RemedyError Detection What to Check Description Corrective ActionAccess Panels Servicing InstructionsTemperature Adjustment Servicing InstructionsRemove Tank LID Assembly Brew Time AdjustmentDripout Time Adjustment Replace Temperature ProbeReplace HOT Water Faucet Coil Replace SolenoidReplace Faucet Supply Hose Repair HOT Water FaucetController Hook-Up Replace Power Board SET Controller JumpersReplace Keypad Procedure Delime the Water Tank Servicing Instructions HOT Water Tank Assembly Description Used onExploded View & Parts List Electrical ComponentsInternal Plumbing Components Faucet Repair KitsCabinet Components Wiring Diagram C. Brewer Genuine Parts
Related manuals
Manual 2 pages 5.03 Kb

1093, 1090, 1092, 1091 specifications

Bloomfield 1090, 1091, and 1092 are highly regarded models in the audio equipment market, specifically designed for professional audio applications like broadcasting, live sound, and recording. These models are noted for their exceptional sound quality, robust construction, and advanced technology that cater to both novice users and seasoned audio engineers.

One of the prominent features of the Bloomfield 1090 model is its sophisticated analog circuitry. This design ensures warm sound reproduction, making it ideal for music production and studio work. The 1090 is equipped with a high-performance preamp that captures audio signals with remarkable clarity and minimal distortion. This makes it a popular choice among sound engineers who prioritize fidelity in their recordings.

The Bloomfield 1091 model builds on the foundation laid by the 1090, introducing digital signal processing capabilities. This integration allows for a range of effects and filters, offering users the flexibility to shape their sound significantly. The 1091 also features a user-friendly interface with an LCD screen that provides real-time feedback on audio levels, allowing users to make precise adjustments on the fly.

Moving on to the Bloomfield 1092, this model stands out due to its versatility and connectivity options. It supports multiple audio input formats, including XLR, TRS, and USB, making it compatible with a wide range of devices. The 1092 is designed for seamless integration into both studio and live performance environments. Its compact size and lightweight construction make it easy to transport, catering to traveling artists and production teams.

In terms of technology, all three models benefit from Bloomfield’s commitment to using high-quality components and innovative engineering. They include features such as built-in limiters, equalizers, and a robust signal routing system that enhances their performance across various applications.

Overall, the Bloomfield 1090, 1091, and 1092 models represent a significant advancement in audio technology, offering unparalleled performance, versatility, and ease of use for audio professionals. Whether in the studio or on the stage, these models deliver unmatched sound quality and reliability, making them a preferred choice for many in the audio industry.