Technical Data
Dimensions in mm: |
|
|
|
|
|
|
| |
Hob H x W x D |
|
| 90 x 680 x 510 |
| ||||
Installation opening W x D |
| 560 x 480 |
|
| ||||
Burner power in kW: |
|
|
|
|
|
|
| |
Small auxiliary burner |
| 1,00 |
|
| ||||
Medium |
| 1,65 |
|
| ||||
Large rapid burner |
| 3,0 |
|
|
| |||
Triple flame burner standard |
| 4,25 |
|
| ||||
Category |
|
|
|
| 2H3+ |
|
| |
|
|
| II |
|
| |||
Gas intake connection |
|
| G 1/2” |
|
| |||
Gas pressure |
|
|
| G20 - 20 mbar |
| |||
Electricity supply |
|
|
| 230 V ~ 50 Hz |
| |||
Appliance class |
|
| 3 |
|
|
|
| |
| MAXIMUM | MINIMUM |
| G 20 | G30/G31 | |||
BURNER | OUTPUT | OUTPUT | 20 mbar | |||||
TYPE | (gcv) |
|
|
|
|
|
|
|
| kW | kW | Nozzle | Nominal | Nozzle | Nominal | ||
|
|
| marking | flow rate | marking | flow rate | ||
|
|
| 100/mm | m3/h | 100/mm | g/h | ||
Small aux burner | 1,00 | 0,30 | 76 |
| 0,095 | 50 | 73 | |
Medium | 1,65 | 0,32 | 94 |
| 0,157 | 65 | 120 | |
Large rapid burner | 3,00 | 0,65 | 128 |
| 0,286 | 85 | 219 | |
T.F. burner std | 4,25 | 1,50 | 63+140 | 0,405 | 37+97 | 310 |
By-pass diameters
Burner | Ø Tap |
Small auxiliary | 27 |
Medium | 29 |
Large rapid | 39 |
Standard | 65 |
12