REMOVING & REPLACING THE DAUGH- TER BOARDS
The Daughter Boards are soldered into the Main Board Assy.
1.Remove the Main Board (Refer to Removing & Replacing the Main Board).
2.Unsolder the appropriate Daughter Board from the Main Board Assembly.
To Replace a Daughter Board:
1.Ensure that the Main Board Assembly and Daugh- ter Board are mechanically clean.
2.Insert the daughter board in the required position.
3.Ensure the Daughter Board is properly seated in the Main Board Assembly.
4.Solder the Daughter Board into position.
zCAUTION: To avoid damage to the Main Board Assembly, soldering must be accomplished quickly. Refer to Component Replacement section of manual located on this page.
REMOVING & REPLACING THE SPEAKER
To remove the speaker:
1.Remove the Main Board (Refer to Removing & Replacing the Main Board).
2.Unscrew the two speaker mounting bracket screws from the chassis.
3.Desolder the two pin wire harness from the speaker.
4.Remove the speaker.
To replace the speaker
1. Reverse the steps taken to remove the speaker.
MAXON
COMPONENT REPLACEMENT
Surface Mount Components
Surface mount components should always be replaced using a temperature controlled soldering system. The soldering tools may be either a temperature controlled soldering iron or a temperature controlled
The following procedures outline the removal and replace- ment of surface mount components. If a
zCAUTION: Avoid applying heat to the body of any surface mount component using standard soldering methods. Heat should be applied only to the metal- ized terminals of the components.
zCAUTION: The CMOS Integrated Circuit devices used in this equipment can be destroyed by static discharges. Before handling one of these devices, service technicians should discharge themselves by touching the case of a bench test instrument that has a
Surface Mount Removal
1.Grip the component with tweezers or small needle nose pliers.
2.Alternately heat the metalized terminal ends of the surface mount component with the soldering iron. If a
3.When the solder on all terminals is liquefied, gently remove the component. Excessive force may cause the PCB pads to separate from the board if all sol- der is not completely liquefied.
Page