INSTRUCTIONS FOR THE INSTALLER

SAFETY ADVICE

Before installation ensure that the local distribution conditions (gas type and pressure) and the pre-setting of the appliance are consistent.

This appliance must be installed only in a room with good ventilation.

This appliance must not connected to a flu. It has to be installed and connected in accordance with the rules in force. Special attention should be paid to the applicable disposal concerning ventilation.

The adjacent furniture panels have to be heat proof or protected by such material.

The adjusting conditions of this appliance are mentioned on the rating plate.

Connection to gas supply.

Check that the gas flow and the diameter of the supply pipe is sufficient to supply all the appliances of the installation.

Check that all connections are tight.

Install an accessible and visible gas tap to isolate the appliance.

ELECTRIC CONNECTION

Any electrical work required to install this cooker should be carried out by a qualified electrician or competent person, in accordance with the current regulations.

This cooker must be earthed.

This cooker is designed to be connected to a 240V 50Hz AC electrical supply.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the rating plate.

Important

We decline any responsibility in case of accidents due to no grounding or wrong grounding.

Important

If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

-Installation of flues and ventilation for gas appliances of rated input not exceeding 60 kW (1st, 2nd and 3rd family gases) – Part 2 Specification for installation of ventilation for gas appliances – BS 5440;

-Gas burning appliances – Part 3 Domestic cooking appliances burning gas – BS 5386;

-Specification for installation of low pressure gas pipe work of up to 20mm (R1) in domestic premises (2nd family gas) – BS 6891;

-Pipe threads for tubes and fittings where pressure-tight joints are made on the threads (metric dimensions) – BS 21: 1985;

-Flexible hoses, end fittings and sockets for gas burning appliances – BS 669;

Installation of domestic gas cooking appliances (1st, 2nd and 3rd family gases) – BS 6172: 1990;

18

Image 18
Contents GSC Page Contents Service Important Safety InformationChild Safety During UseControl panel Description of the ApplianceHob Model GSC 5061 WTechnical Features Using the Appliance Before the First Use of the CookerIgnition Gas MarkCondensation and steam CookwareUsing the Grill Grill burner ignitionGrilling Hob Burners Grilling meatBrowning Ignition of the burnersAccessories delivered with the appliance Selecting the Correct burnerExtinguishing of burners Maintenance and Cleaning Hob BurnersSymptoms Solutions Something not WorkingService and Spare Parts Customer CareEuropean Guarantee Guarantee ConditionsStandard Guarantee Conditions ExclusionsInstructions for the Installer Connection to gas supplyThis cooker must be earthed Technical Data InstallationPositioning Ventilation Left Hand Connection from front GAS ConnectionsRight Hand Connection from front Fixing and use of the 2 clips provided with the cookerPage YES Adjustment of minimum level for the hob burners Conversion of GASReplace the nozzles of the oven burners Oven burner Flame adjustment Oven burnersTable no.2 Gas type Air adjusting mm Oven Grill Grill burnerAdjustment of minimum level Oven burner