CLEANING
The conveyor chain should not touch the top surface of the crumb tray holder. If the chain does touch, retension it by un plugging the unit, remove both side covers, loosen the front bearing mounting screws and pivot the bearing until the chain no longer touches.
CLEANING
1.Set the POWER switch to OFF. Allow toaster to cool for 30 minutes.
2.Unplug toaster.
3.Remove crumb tray and clean toaster and parts by wiping with damp cloth.
Note: Some units come with a Teflon coated return chute. Do Not use an abrasive cleaning agent or scrub brush on the Teflon.
CAUTION: Turn off power switch, unplug toaster from wall outlet, and let toaster cool down before doing any repairs. All repairs should be done by a qualified service technician.
TROUBLESHOOTING CHART
PROBLEM | CAUSE | SOLUTION |
|
|
|
High limit tripped. | Toaster overheating due to | Clean any debris from the fan guard |
| blockage of airflow. | that might be blocking the flow. |
| Airflow fan inoperable. | Replace fan . |
|
|
|
No power. | Circuit breaker tripped. | Reset circuit breaker. |
| Power switch inoperable. | Replace power switch. |
| Broken wire in power cord. | Replace power cord. |
|
|
|
Toaster conveyor not | Conveyor motor inoperable. | Lubricate and/or Replace motor. |
turning. | Conveyor switch inoperable. | Replace speed switch. |
| Motor chain is loose | Retension motor chain. |
| Conveyor bearings worn | Replace bearings |
|
|
|
Conveyor chain binds | Sprockets worn. | Replace sprockets. |
up in operation. | Excessive slack in conveyor | Remove a chain link. |
| chain. |
|
|
|
|
Toaster overheating. | Airflow blockage. | Clean any debris from fan guard |
| Airflow fan inoperable | Replace fan motor. |
|
|
|
Upper and lower heat | Heater switch inoperable. | Replace heater switch. |
tubes not heating. | Heater tube inoperable. | Replace heater tube. |
|
|
|
Bread product burning. | Conveyor speed too slow. | Adjust to proper settings |
|
|
|
Bread product too light. | Conveyor speed too fast. | Adjust to proper settings |
|
|
|
Lower heat tubes heating | High Limit Switch Tripped | See High Limit Tripped section |
but top tubes are not. |
|
|
|
|
3