TROUBLESHOOTING

Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to

voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.

PROBLEM

CAUSE

CORRECTION

Excessive tank

Pressure switch does not

Move On/Auto/Off lever

pressure - safety

shut off motor when com-

to the "OFF" position, if

valve pops off.

pressor reaches "cut-out"

the outfit does not shut off

 

pressure.

contact a Trained Service

 

 

Technician.

 

Pressure switch "cut-out"

Contact a Trained Service

 

too high.

Technician.

 

 

 

Air leaks at fit-

Tube fittings are not tight

Tighten fittings where air can

tings.

enough.

be heard escaping. Check fit-

 

 

tings with soapy water solu-

 

 

tion. Do Not Overtighten.

Air leaks at or

Check valve seat damaged.

A defective check valve

inside check

 

results in a constant air leak

valve

 

at the pressure release valve

 

 

when there is pressure in the

 

 

tank and the compressor

 

 

is shut off. Replace check

 

 

valve. Refer the "To Replace

 

 

or Clean Check Valve" in the

 

 

"Service and Adjustment"

 

 

section.

 

 

 

Air leaks at

Defective pressure switch

Contact a Trained Service

pressure switch

release valve.

Technician.

release valve.

 

 

Air leaks in air

Defective air tank.

Air tank must be replaced.

tank or at air

 

Do not repair the leak.

tank welds.

 

Risk of

 

 

Bursting.

 

 

Do not drill into, weld or

 

 

otherwise modify air tank

 

 

or it will weaken. The tank

 

 

can rupture or explode.

 

 

 

Air leaks

Leaking seal.

Contact a Trained Service

between head

 

Technician.

and valve plate.

 

 

 

 

 

21- ENG

A14411

Page 21