To Replace Regulator
1.Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.
2.Set the On/Auto/Off lever to "OFF" and unplug unit.
3.Remove the outlet pressure gauge and quick connect (if equipped) from the regulator.
| Outlet | |
| Pressure | |
| Gauge | |
Regulator | Quick | |
Connect | ||
|
4.Remove the regulator.
5.Apply pipe sealant tape to the nipple.
Nipple
6.Assemble the regulator and ori- ent as shown.
Regulator
NOTE: Arrow indicates flow of air. Make sure it is pointing in the direc- tion of air flow.
Regulator
Arrow
7. Reapply pipe sealant to outlet pressure gauge and quick con- nect.
8. Reassemble outlet pressure gauge and quick connect. Orient outlet pressure gauge to read correctly. Tighten quick connect with wrench.