Lincoln II - Advantage Series REMOVAL, INSTALLATION, and Adjustment, MOTOR, Main FAN, FAN, Main

Page 17

REMOVAL, INSTALLATION, AND ADJUSTMENT

IMPINGER II ADVANTAGE

CAUTION!

BEFORE REMOVING OR INSTALLING ANY COMPONENT IN THE IMPINGER OVEN, BE SURE TO DISCONNECT

ELECTRICAL POWER AND GAS SUPPLY.

MOTOR, MAIN FAN

1.Shut off power at main breaker.

2.Remove motor cover from back of oven.

3.Remove wires for motor and mark for reassembly.

4.Remove hex head bolts from the oven back and slide back straight out of the oven.

5.Loosen bolt from fan hub and remove fan from motor shaft.

NOTE: Measure distance from fan blade to rear wall assembly before removal to aid in reassembly.

6.Remove the bolts from the motor mount and remove motor clamp. Slide the motor assembly out of the oven back.

7.Remove motor by removing the four (4) mounting nuts and washers.

8.Reassemble in reverse order. When motor mount assembly is set on the oven back, align motor shaft in the center of the hole. Set fan assembly on the motor shaft.

NOTE: It is recommended that an anti-seize compound be brushed on to the bolts around the back and motor mount bracket before assembly.

FAN, MAIN

1.Shut off power at main breaker.

2.Remove back assembly. (See motor, main fan)

3.Reinstall and locate fan so that the bottom of the fan spider is 1 1/2" from the top of the oven back cone. (See drawing)

FAN SPIDER

FAN HUB

CONE

NOTE: MEASUREMENT MUST BE

MADE FROM CONE TO FAN SPIDER

1 1/2 INCH

CAPACITOR, MOTOR

1.Shut off power at main breaker.

2.Remove control box cover and front panel.

3.Discharge capacitor.

4.Remove and replace.

ON/OFF SWITCH - REPLACEMENT

1.Shut off power at main breaker.

2.Remove control box cover.

3.Remove front panel.

4.Depress spring clips on side of switch and push out.

5.Remove wires from back of switch, note wire number and location.

6.Reassemble in reverse order and check system operation. NOTE: Make sure switch housing is fully seated in control box housing.

Impinger II –Advantage Service Manual - Domestic

17

Image 17
Contents Impinger Conveyor Ovens Table of Contents Impinger II Advantage Sequence of OperationsHeater Circuit Control BOX Auto Cool DownSchematic 1116-000-A, 1117-000-A Schematic 1130-000-A / 1131-000-A Schematic 1132-000-A / 1133-000-A Phase Troubleshooting Guide / GAS OvensNatural GAS LP GASPage Attached to the Temperature Control With Power on and Thermocouple LeadsPage Page Single Phase Troubleshooting Guide / Electric OvensThree Phase Refer to Proper Schematic for Identified ComponentsLeads Attached to the Temperature With Power on and ThermocouplePage Page ON/OFF Switch Replacement REMOVAL, INSTALLATION, and AdjustmentMOTOR, Main FAN FAN, MainTHERMOSTAT, Control BOX HI-LIMIT Replacement Fuse Holder ReplacementBurner Blower Motor Replacement High Limit Thermostat ReplacementThermocouple Replacement Burner Transformer ReplacementThermocouple Measurement Chart InformationElectronic Temperature Control Board Calibration Electronic Temperature Control Board ReplacementTemperature Control Potentiometer Replacement Heat Light ReplacementHOT Surface Ignitor Replacement Temperature Regulation Valve ReplacementMain Burner Orifice Replacement Conveyor Control Potentiometer ReplacementConveyor Drive Motor Replacement Conveyor Control Board ReplacementConveyor Control Board Calibration Circuit BreakerTemperature Display Transformer Replacement Hall Effect Sensor ReplacementTemperature Display Replacement Calibration of Temperature DisplayBEARING, Conveyor Heating Element ReplacementThis page intentionally left blank Letter Part Number Description Parts / GeneralBlow UP / General Parts / Control BOX 1116-000-A, 1117-000-A Blow UP / Control BOX 1116-000-A, 1117-000-A Parts / Control BOX 1130-000-A Thru 1133-000-A Blow UP / Control BOX 1130-000-A Thru 1133-000-A Parts / Conveyor & Door Blow UP / Conveyor & Door Parts / Oven Back Assembly Blow UP / Oven Back Assembly