TROUBLESHOOTING GUIDE / GAS OVENS
| MODEL | NATURAL GAS | 120 VAC | 60 HZ | 1 PHASE | |||
| MODEL | LP GAS |
| 120 VAC | 60 HZ | 1 PHASE | ||
|
|
|
|
|
|
| ||
| SYMPTOM | POSSIBLE CAUSE | EVALUATION |
|
|
| ||
| Oven fan will not run | Incoming Power Supply | Check breakers, reset it required. Check power plug | |||||
|
|
|
| to be sure it is firmly in receptacle. Measure | ||||
|
|
|
| incoming power/call power company if needed. | ||||
|
| Fuse, 10 Amp |
| Check, replace if necessary. |
|
| ||
|
| Fuse Holder |
| Check, replace if necessary. |
|
| ||
|
| Hi Limit | Check for voltage on both sides of the switch. | |||||
|
| Box |
| Terminals are normally closed. If open, reset and | ||||
|
|
|
| test oven for proper operation. If thermostat will not | ||||
|
|
|
| hold and control box temperature is not exceeding | ||||
|
|
|
| 140°F (60°), replace thermostat. | ||||
|
| Main Fan Switch |
| Check continuity between switch terminals. | ||||
|
| Main Fan Motor |
| Check for opens, shorts, or grounds. WITH POWER | ||||
|
|
|
| OFF turn fan blade to check for locked rotor. | ||||
|
| Capacitor |
| Check for shorts or grounds. |
|
| ||
|
|
|
| WARNING: Capacitor has a stored charge, | ||||
|
|
|
| discharge before testing. |
|
| ||
| No control box cooling | Incoming Power |
| Check main circuit breakers, reset if required, call | ||||
|
|
|
| power company if needed. |
|
| ||
|
| Main Fan Switch |
| Check continuity between switch terminals | ||||
|
| Cooling Fan |
| 120 VAC should now be at the fan motor. If voltage | ||||
|
|
|
| is present, check motors for shorts or opens. WITH | ||||
|
|
|
| POWER OFF: Check for locked rotor. | ||||
| No automatic control | Incoming Power Supply | Check circuit breakers, |
|
| |||
| box cooling |
|
| reset if required. Call the power company if needed. | ||||
|
| Cooling Fan Thermostat | Check the cooling fan thermostat. (Thermostat | |||||
|
|
|
| closes at 120°F and opens at 100°F). With the | ||||
|
|
|
| cooling fan thermostat preheated, check for | ||||
|
|
|
| continuity. If switch is open, replace. | ||||
|
| Cooling Fan |
| 120 VAC should be at the motor. If voltage is | ||||
|
|
|
| present, check motor for shorts, opens, or grounds. | ||||
|
|
|
| WITH POWER OFF: check for locked rotor. | ||||
| Oven will not heat | Gas Supply |
| Check for adequate gas supply and closed manual | ||||
|
|
|
| gas shut offs. Also, check flexible gas line | ||||
|
|
|
| connection. |
|
|
| |
|
| Main Fan |
| If not operating, refer to "Oven fan will not run". | ||||
|
| High Limit Oven Cavity | Terminals are normally closed. If | |||||
|
| Thermostat |
| open, push in reset button and retest. If thermostat | ||||
|
|
|
| will not hold for maximum oven temperature, and | ||||
|
|
|
| oven is not exceeding temperature dial setting, | ||||
|
|
|
| check for proper location of capillary bulb in its | ||||
|
|
|
| spring holder. If above checks okay, replace | ||||
|
|
|
| thermostat. |
|
|
| |
|
| Centrifugal Switch | Check for 120 VAC at lead #9 |
|
| |||
|
| of Main Fan Motor | (located at 6 pin connector in raceway near the main | |||||
|
|
|
| fan motor) to neutral. If no voltage is present, and | ||||
|
|
|
| motor is running, replace motor. | ||||
8 |
|
|
| Impinger II – Advantage Service Manual - Domestic |