| occur. If flame is not detected, the ignition control will |
|
| shut off and lock out. To reset the ignition control, |
|
| turn off the power switch for 45 seconds, then turn |
|
| the switch on to |
|
| requires a minimum of 0.8 DC microamps to prove |
|
| flame. To check flame sensing operation, connect a |
|
| digital multimeter (capable of measuring DC |
|
| microamps) between the “ground” terminal on |
|
| ignition control and the ground lead. |
|
| NOTE: This is a current measurement and the meter |
|
| must be connected in series |
|
| If these readings are not achieved, replace hot |
|
| surface igniter. |
|
| NOTE: The DC microamp test must be conducted |
|
| with the oven in low flame (bypass) operation. Set |
|
| the temperature control to the lowest setting. |
| Power supply | If there is sufficient microamp current, but the flame |
|
| will not stay lit, check for proper polarity of the |
|
| 120VAC power supply. |
| Ignition control | If there is sufficient microamp current, and the |
|
| 120VAC polarity is correct, but the flame will not stay |
|
| lit, replace the ignition control. |
|
| NOTE: Check for proper ground connection on |
|
| ignition control. |
| NOTE: Flame should be on at |
|
| this time |
|
|
|
|
Low flame is on, | Control transformer | Check for 120VAC supply to the primary of the |
but no main flame |
| control transformer. If no voltage is present, trace |
|
| wiring back to the main power switch. If voltage is |
|
| present, check for 24VAC at the transformer |
|
| secondary. If there is primary voltage, but no |
|
| secondary voltage, replace the control transformer. |
| Oven control | Check for 24VAC supply to control. If no voltage is |
|
| present, trace wiring back to control transformer. If |
|
| 24VAC is present, check for a |
|
| display. If there is 24VAC supplied, but there is no |
|
| |
|
| control. |
|
| If there is a |
|
| maximum temperature (see installation operations |
|
| manual for temperature adjustment). With the control |
|
| set at maximum temperature, check for 120VAC at |
|
| the temperature regulation valve. If there is voltage at |
|
| the temperature regulation valve, proceed to |
|
| “Temperature regulation valve” for next check. If |
|
| there is no voltage at the temperature regulation |
|
| valve, trace wiring back to the oven control. If there is |
|
| no voltage output at the oven control, check the read- |
|
| out on the control. If the control reads “PROBE |
|
| FAIL”, this indicates that the thermocouple has failed |
|
| or become disconnected from the oven control. |
| Thermocouple | Check to be sure that the thermocouple is securely |
|
| connected to the oven control. If the thermocouple is |
|
| connected to the oven control, and the control |
|
| indicates “PROBE FAIL”, disconnect the |
|
| thermocouple from the oven control and measure the |
|
| resistance of the thermocouple. The thermocouple |
|
| should read approx. 11Ω. If these readings are not |
|
| achieved, replace the thermocouple. If these |
|
| readings are correct, proceed. |
Impinger II – Advantage Digital Express Service Manual - Domestic | 13 |