Lincoln 1162-080-A, 1132-080-A, 1131-08H-A, 1132-08H-A, 1116-080-A1 Replace relay as needed

Page 17

 

 

Replace relay as needed.

Main fan runs after

Oven start relay

Contacts should open when main power switch is

20 minute cool down

 

turned off. Replace relay as needed.

 

20 Minute time delay

120VAC at terminal #2 should discontinue approx.

 

 

20 minutes after main power is switched off. If the

 

 

oven start relay contacts are open, and the

 

 

voltage continues at terminal #2 of the 20 minute

 

 

timer, for more than 20 minutes, replace the 20

 

 

minute time delay.

 

Oven fan relay

Check to insure that the relay contacts are

 

 

opening after the relay coil is de-energized.

 

 

Replace relay as needed.

 

20 Minute time delay

NOTE: On/ off operation of the main power switch

 

 

will set the timer to 20 minutes. If the timer is

 

 

accidentally reset, turn off the main circuit breaker

 

 

for 15 seconds to cancel.

No control box cooling

Incoming power

Check circuit breakers, reset if required. Check

 

 

power plug to be sure it is firmly in receptacle.

 

 

Measure incoming power, call power co. if

 

 

needed.

 

Switch, main power

Check continuity between switch terminals.

 

 

Replace switch as needed.

 

Cooling fan

Check for supply voltage at cooling fan. If no

 

 

voltage is present, trace wiring back to power

 

 

switch. If voltage is present, and motor does not

 

 

run, check for opens, shorts or grounds.

 

 

WITH POWER OFF: Check for locked rotor.

No automatic control box

Incoming power supply

Check circuit breakers, reset if required. Check

cooling

 

power plug to be sure it is firmly in receptacle.

 

 

Measure incoming power, call power co. if

 

 

needed.

 

Cooling fan thermostat

Check the cooling fan thermostat. (Thermostat

 

 

closes at 120°F and opens at 100°F). With the

 

 

cooling fan thermostat pre-heated, check for

 

 

continuity. If switch is open, replace cooling fan

 

 

thermostat.

 

Cooling fan

Check for supply voltage at cooling fan. If no

 

 

voltage is present, trace wiring back to cooling fan

 

 

thermostat. If voltage is present, and motor does

 

 

not run, check for opens, shorts or grounds.

 

 

WITH POWER OFF: Check for locked rotor.

Oven will not heat

Main fan motor

Check for main fan operation. If it is not operating,

 

 

refer to “Oven fan will not run”.

 

Air pressure switch

This normally open switch should close when the

 

 

main fan is activated. Refer to the “Removal and

 

 

installation” section for proper adjustment.

 

 

Replace as needed.

 

Control transformer

Check for 120VAC supply to the primary of the

 

 

control transformer. If no voltage is present, trace

 

 

wiring back to the main power switch. If voltage is

 

 

present, check for 24VAC at the transformer

 

 

secondary. If there is primary voltage, but no

 

 

secondary voltage, replace the control

 

 

transformer.

 

Oven control

Check for 24VAC supply to control. If no voltage is

 

 

present, trace wiring back to control transformer. If

 

 

24VAC is present, check for a read-out on the

 

 

display. If there is 24VAC supplied, but there is no

 

 

read-out on the control display, replace the oven

 

 

control.

Impinger II – Advantage Digital Express Service Manual - Domestic

17

Image 17
Contents Impinger Conveyor Ovens LP GAS PhaseNAT. GAS 1130-080-A 120/208VAC 60 HZ Schematic Diagram Model 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1 Model 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1 Model 1161-080-A Model 1162-080-A Model 1130-08H-A, 1131-08H-A Model 1132-08H-A, 1133-08H-A Symptom Possible Cause Evaluation Troubleshooting Guide GAS OvensMain fan motor to neutral. If no voltage is Occur. If flame is not detected, the ignition control will With Power on and Thermocouple Troubleshooting Guide Electric Ovens Phase Replace relay as needed If there is a read-out on the control, set the control Thermal protection and will cease to operate if MOTOR, Main FAN Replacement REMOVAL, Installation and AdjustmentsON/OFF Switch Replacement Capacitor ReplacementFuse Holder Replacement Cooling FAN, Control BOX ReplacementOven Control Replacement TRANSFORMER, Burner ReplacementTransformer Control Replacement Thermocouple ReplacementGAS Valve Replacement Burner Control ReplacementTemperature Regulation Valve Replacement HOT Surface Igniter ReplacementMain Burner Orifice Replacement Bypass Orifice ReplacementReversing Switch Replacement Conveyor Drive Motor ReplacementHeating Element Replacement BEARING, Conveyor ReplacementMercury Contactor Replacement Letter Part Number Description General View Impinger II Advantage ModelGeneral View 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1 Control BOX, Front ModelControl BOX, Front View Model Control BOX, Front Model Control BOX, Front View Model Control BOX, Rear Model Control BOX, Rear View Model Control BOX Rear Model Control BOX, Rear View Model Letter Part Number Oven Back AssemblyOven Back Assembly View Conveyor / Door Conveyor / Door View