BURNER CONTROL – REPLACEMENT

A.Shut off power at main breaker.

B.Remove conveyor and front control box cover.

C.Remove wires from control and mark for reassembly.

D.Remove mounting screws from control and remove burner control.

E.Reassemble in reverse order and check system operation.

GAS VALVE – REPLACEMENT

A.Shut off power at main breaker.

B.Shut off gas supply to the oven and disconnect the flexible gas line to oven.

C.Remove rear control box cover.

D.Remove the manual gas shut-off valve.

E.Remove screws from the bulkhead plate on inlet gas pipe and remove inlet gas pipe.

F.Remove pilot tube and wiring from gas valve, Mark all wiring for reassembly.

G.Disconnect pipe union in gas line and remove gas valve and piping assembly.

H.Remove piping from gas valve.

I.Reassemble in reverse order and check system operation.

J.Check all gas line fitting for leaks.

K.Adjust the gas manifold pressure on the gas valve. Refer to the specification plate on the oven for proper rating.

TEMPERATURE REGULATION VALVE – REPLACEMENT

A.Shut off power at main breaker.

B.Shut off gas supply to the oven and disconnect the flexible gas line to oven.

C.Remove rear control box cover.

D.Remove bypass tube from burner manifold.

E.Remove wiring from valve and mark for reassembly.

F.Remove four mounting nuts from burner manifold and disconnect pipe union.

G.Remove temperature regulation valve and piping from oven.

HOT SURFACE IGNITER – REPLACEMENT

A.Shut off power at main breaker.

B.Shut off gas supply to the oven and disconnect the flexible gas line to oven.

C.Remove conveyor and control box covers.

D.Remove temperature regulation valve. See “TEMPERATURE REGULATION VALVE”.

E.Disconnect wires from burner control.

F.Remove three mounting screws and remove burner venturi.

G.Remove mounting nut and remove hot surface igniter assembly.

H.Reassemble in reverse order and check system operation.

I.Check all gas line fittings for leaks.

Impinger II – Advantage Digital Express Service Manual - Domestic

23

Image 23
Contents Impinger Conveyor Ovens LP GAS PhaseNAT. GAS 1130-080-A 120/208VAC 60 HZ Schematic Diagram Model 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1 Model 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1 Model 1161-080-A Model 1162-080-A Model 1130-08H-A, 1131-08H-A Model 1132-08H-A, 1133-08H-A Symptom Possible Cause Evaluation Troubleshooting Guide GAS OvensMain fan motor to neutral. If no voltage is Occur. If flame is not detected, the ignition control will With Power on and Thermocouple Troubleshooting Guide Electric Ovens Phase Replace relay as needed If there is a read-out on the control, set the control Thermal protection and will cease to operate if MOTOR, Main FAN Replacement REMOVAL, Installation and AdjustmentsCooling FAN, Control BOX Replacement Capacitor ReplacementON/OFF Switch Replacement Fuse Holder ReplacementThermocouple Replacement TRANSFORMER, Burner ReplacementOven Control Replacement Transformer Control ReplacementHOT Surface Igniter Replacement Burner Control ReplacementGAS Valve Replacement Temperature Regulation Valve ReplacementConveyor Drive Motor Replacement Bypass Orifice ReplacementMain Burner Orifice Replacement Reversing Switch ReplacementHeating Element Replacement BEARING, Conveyor ReplacementMercury Contactor Replacement Letter Part Number Description General View Impinger II Advantage ModelGeneral View 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1 Control BOX, Front ModelControl BOX, Front View Model Control BOX, Front Model Control BOX, Front View Model Control BOX, Rear Model Control BOX, Rear View Model Control BOX Rear Model Control BOX, Rear View Model Letter Part Number Oven Back AssemblyOven Back Assembly View Conveyor / Door Conveyor / Door View