Lincoln 1132-08H-A, 1162-080-A, 1132-080-A, 1131-08H-A, 1116-080-A1 1130-080-A 120/208VAC 60 HZ

Page 3

SEQUENCE OF OPERATION

IMPINGER II ADVANTAGE, ELECTRIC

(OVENS WITH PUSH BUTTON CONTROLS)

1130-080-A

120/208VAC

60 HZ.

1 PHASE

1130-080-A1

120/208VAC

60 HZ.

1 PHASE

1130-08H-A

208 VAC

60 HZ.

1 PHASE

1131-080-A

120/240VAC

60 HZ.

1 PHASE

1131-080-A1

120/240VAC

60 HZ.

1 PHASE

1131-08H-A

240 VAC

60 HZ.

1 PHASE

1132-080-A

120/208VAC

60 HZ.

3 PHASE

1132-080-A1

120/208VAC

60 HZ.

3 PHASE

1132-08H-A

208 VAC

60 HZ.

3 PHASE

1133-080-A

120/240VAC

60 HZ.

3 PHASE

1133-080-A1

120/240VAC

60 HZ.

3 PHASE

1133-08H-A

240 VAC

60 HZ.

3 PHASE

1161-080-A

120/240VAC

60 HZ.

1 PHASE

1162-080-A

120/208VAC

60 HZ.

3 PHASE

POWER SUPPLY

CONTROL BOX AUTO COOL DOWN

MAIN FAN CIRCUIT

TEMPERATURE CONTROL

CONVEYOR DRIVE

AUTOMATIC COOL DOWN

Electrical power to be supplied to the oven by a three conductor service for single phase and a four conductor service for three phase.

Black conductor is hot. Red conductor is hot.

Orange conductor is hot (used for three phase only). White conductor is neutral.

Green conductor is ground.

When the temperature in the control box reaches 120°F ± 3° (48.9°C ± 1.7°), the cooling fan thermostat will switch power to the control box cooling fans. The thermostat will interrupt power to the cooling fans when the control box temperature falls to 100°F ± 3° (37.8°C ± 1.7°).

Power is permanently supplied through the 10 amp fuses, through the normally closed oven cavity hi-limit thermostat, to the normally open main power switch. Power is also supplied to the normally open cooling fan thermostat. Closing the main power switch energizes the coil of the oven start relay, it’s contacts close enabling the 20 minute time delay relay. The 20 minute time delay relay supplies 120VAC to the oven fan relay, these normally open contacts now close supplying 208/240VAC to the main fan motor. 120VAC is also supplied to the cooling fans. 208/240VAC is supplied to the primary of the control transformer, the conveyor motor and, through the air pressure switch, to the oven control. Closing the main power switch supplies 208/240VAC to the primary of the control transformer. Secondary voltage, 24VAC, is supplied to the oven control. The oven control is set to desired temperature. The thermocouple will provide varying millivolts to the oven control. The oven control supplies 208/240VAC to the coil of the heater relay at intermittent intervals to maintain the desired temperature. The display on the oven control will indicate when the heater relay is energized.

NOTE: The display also indicates oven temperature.

Closing the main power switch supplies 208/240VAC to the conveyor motor and to the primary of the control transformer. Secondary voltage, 24VAC, is supplied to the oven control. Setting the oven control to the desired time outputs voltage, through a reversing switch, to the conveyor motor.

NOTE: The conveyor system uses a hall effect sensor and magnet to prove operation of the conveyor motor. If the conveyor motor is not running, “BELT JAM” is indicated on the display.

When the oven is started, the time delay relay timing circuit is enabled, permitting the oven fans to run approximately 20 minutes after the oven is shut off, to cool the oven. The time delay relay will keep the coil of the fan relay closed, maintaining operation of the main fan and cooling fans.

Impinger II – Advantage Digital Express Service Manual - Domestic

3

Image 3
Contents Impinger Conveyor Ovens Phase NAT. GASLP GAS 1130-080-A 120/208VAC 60 HZ Schematic Diagram Model 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1 Model 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1 Model 1161-080-A Model 1162-080-A Model 1130-08H-A, 1131-08H-A Model 1132-08H-A, 1133-08H-A Symptom Possible Cause Evaluation Troubleshooting Guide GAS OvensMain fan motor to neutral. If no voltage is Occur. If flame is not detected, the ignition control will With Power on and Thermocouple Troubleshooting Guide Electric Ovens Phase Replace relay as needed If there is a read-out on the control, set the control Thermal protection and will cease to operate if MOTOR, Main FAN Replacement REMOVAL, Installation and AdjustmentsCooling FAN, Control BOX Replacement Capacitor ReplacementON/OFF Switch Replacement Fuse Holder ReplacementThermocouple Replacement TRANSFORMER, Burner ReplacementOven Control Replacement Transformer Control ReplacementHOT Surface Igniter Replacement Burner Control ReplacementGAS Valve Replacement Temperature Regulation Valve ReplacementConveyor Drive Motor Replacement Bypass Orifice ReplacementMain Burner Orifice Replacement Reversing Switch ReplacementBEARING, Conveyor Replacement Mercury Contactor ReplacementHeating Element Replacement Letter Part Number Description General View Impinger II Advantage ModelGeneral View 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1 Control BOX, Front ModelControl BOX, Front View Model Control BOX, Front Model Control BOX, Front View Model Control BOX, Rear Model Control BOX, Rear View Model Control BOX Rear Model Control BOX, Rear View Model Letter Part Number Oven Back AssemblyOven Back Assembly View Conveyor / Door Conveyor / Door View