Vertex Standard manual 1.2 7122B/7133B OU Drive Cabinet

Page 6

INTRODUCTION

·Power Supply

·Resolver/Digital PC Board

·Display Board Assembly

·Binary/BCD Board Assembly

·Switch PC Board Assembly

The front panel contains the POWER ON/OFF switch that controls the power to the circuit boards on the 7122B/7133B ACU.

The 7122/7133 Controller Resolver to Digital PC Board Assembly (800029) converts the analog output of the elevation, azimuth, and polarization resolvers to digital.

The 7122/7133 A, B, and C Antenna Control Unit Front PC Board (800026) contains seven-segment displays and associated circuitry for display of the elevation, azimuth, and polarization positions of the antenna.

The Front Switch PC Board (800032 - 7133B; 800050 - 7122B) contains three- position momentary on/off switches that control the elevation, azimuth, and polarization movement of the antenna.

1.2.1.2 7122B/7133B OU Drive Cabinet

The 7122B/7133B OU consist of the following major components:

·Swing-Out Panel

·MAIN POWER Circuit Breaker

·EMERGENCY STOP Switch

·24 VDC Power Supply

·Reversing Starters

·Relay PC Board

The swing-out panel allows the operator to control antenna movement from the proximity of the antenna.

The MAIN POWER circuit breaker controls the main power and the power to the OU cabinet and the limit switches.

The EMERGENCY STOP switch, when pressed, removes power from the drive motors.

The 24 VDC power supply provides operating voltage to the 7122B/7133B OU antenna drive relay circuit board.

1 - 2

Image 6
Contents CG-1045 AprilProprietary Notice Please Read the Following Precautions Table of Contents General Information about the 7122B/7133B ACU IntroductionPurpose of the 7122B/7133B Manual System Hardware1.2 7122B/7133B OU Drive Cabinet Installing the 7122B/7133B ACU Installation and Initial SET-UPMechanical Installation Antenna Mounted Components OverviewB Antenna Control System Block Diagram Shows the connections between the ACU and the OU Display Offset Adjustment Resolvers are connected as shown in TableOperation 7122B/7133B ACU7122B/7133B OU 1 7122B/7133B OU Controls 7122B/7133B OU Controls FunctionAcceptance Test Procedure Maintenance ModePreliminary Information Remote Mode ATP Recommended Spares Engineering Drawings Appendix a Acronyms and Abbreviations CrlfFLT PCB Appendix B Technical Support FAX 903 Model