Table 2-1 shows the connections between the ACU and the OU.

TABLE 2-1. 7122B/7133B ACU CONNECTIONS TO 7122B/7133B OU

ACU, J8 PIN NO.

FUNCTION

OU TERMINAL STRIP

 

 

 

1

AZ CW COMMAND

1

 

 

 

2

AZ COMMON

2

 

 

 

3

AZ CCW COMMAND

3

 

 

 

4

EL UP COMMAND

4

 

 

 

5

EL COMMON

5

 

 

 

6

EL DOWN COMMAND

6

 

 

 

7

POL CW COMMAND

7

 

 

 

8

POL COMMON

8

 

 

 

9

POL CCW COMMAND

9

 

 

 

10

AZ CW LIMIT

10

 

 

 

11

AZ CCW LIMIT

11

 

 

 

12

EL UP LIMIT

12

 

 

 

13

EL DOWN LIMIT

13

 

 

 

14

POL CW LIMIT

14

 

 

 

15

POL CCW LIMIT

15

 

 

 

16

EMERGENCY STOP

16

 

 

 

17

GROUND

17

 

 

 

18

GROUND

18

 

 

 

19

+24V

19

 

 

 

20

+24V

20

 

 

 

2 - 3

Image 9
Contents April CG-1045Proprietary Notice Please Read the Following Precautions Table of Contents Purpose of the 7122B/7133B Manual IntroductionGeneral Information about the 7122B/7133B ACU System Hardware 1.2 7122B/7133B OU Drive Cabinet Mechanical Installation Antenna Mounted Components Installation and Initial SET-UPInstalling the 7122B/7133B ACU OverviewB Antenna Control System Block Diagram Shows the connections between the ACU and the OU Resolvers are connected as shown in Table Display Offset AdjustmentOperation 7122B/7133B ACU7122B/7133B OU 7122B/7133B OU Controls Function 1 7122B/7133B OU ControlsAcceptance Test Procedure Maintenance ModePreliminary Information Remote Mode ATP Recommended Spares Engineering Drawings Crlf Appendix a Acronyms and AbbreviationsFLT PCB Appendix B Technical Support Model FAX 903