SEQUENCE OF OPERATION

Power Supply

Heating Circuit

Electrical power is supplied to the unit by a 3 conductor service for single phase.

120VAC

Black conductor is hot. White conductor is neutral.

Green and yellow conductor is ground.

Power is permanently supplied to the main power switch.

Closing the main power switch supplies voltage to the power board and user interface.

Temperature is set through the user interface which then intermittently supplies 120VAC to the heater plates. Temperature is then controlled by the thermocouples sending a reference signal back to the user interface.

Holding Cabinet – Service Manual

5

Image 5
Contents Merco Holding Cabinet Specifications Model MHC-22-GEN Control PanelWiring Diagram Sequence of Operation Symptom Possible Cause Evaluation Troubleshooting GuideUser Interface U.I. Board Replacement Troubleshooting Guide CONT’DHeat Shelf Replacement Label Part Number Part Description Parts BreakdownGeneral View Diagnostic Mode ErNN