Merco Savory 86002 service manual Troubleshooting Guide CONT’D, Heat Shelf Replacement

Page 7

TROUBLESHOOTING GUIDE (CONT’D)

 

 

 

Display reads

 

Make sure wires are connected properly

unusual characters

 

(grounded).

 

 

If wires are grounded properly, new control board

 

 

is needed.

 

 

 

On/Off switch doesn’t

Power Switch

Check wiring to switch.

light (but unit works

 

 

properly)

 

 

HEAT SHELF – REPLACEMENT

1.Disconnect power.

2.Take out screws holding “L Brackets” in cavity.

3.Disconnect thermocouple and all power connections to board. Mark all wires for reassembly.

4.Take out power board.

5.Take out shelf mounting screws from both sides.

6.Remove shelves and feed wiring out of unit.

Be careful to avoid tearing the aluminum foil while working with wire ! WARNING: connections.

7. Reassemble in reverse order.

USER INTERFACE (U.I.) BOARD – REPLACEMENT

1.Remove four (4) screws.

2.Disconnect thermocouples.

3.Disconnect ribbon cable.

4.Remove board.

5.Reassemble in reverse order.

When replacing U.I. board, be sure ribbon cable is connected

! so that blue wire is facing towards interior of unit.

Holding Cabinet – Service Manual

7

Image 7
Contents Merco Holding Cabinet Specifications Model MHC-22-GEN Control PanelWiring Diagram Sequence of Operation Symptom Possible Cause Evaluation Troubleshooting GuideHeat Shelf Replacement Troubleshooting Guide CONT’DUser Interface U.I. Board Replacement Label Part Number Part Description Parts BreakdownGeneral View Diagnostic Mode ErNN