Component Specifications
!WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing, unless testing requires power.
Illustration | Component | Test Procedure | Results |
| Dishwasher Motor | Measure resistance from |
|
|
| ST5 (Motor Common – blue) to ST8 |
|
| CCW rotation only | (Motor Main - yellow) | 3 to 4 Ω |
| viewed from shaft | See Component Specifications/Motor |
|
| end. | Connections for details. |
|
| 1/3HP |
|
|
| 120V/60hz, 3.2 amps, |
|
|
| 3250 RPM |
|
|
| Main Wattage, 285 |
|
|
| watts |
|
|
| Start Wattage, 1115 |
|
|
| watts |
|
|
| Control Board | See Component Specifications/ |
|
|
| Membrane Readings for |
|
|
|
|
Water valve | Measure resistance from |
|
| J6 Pin 4 Aqua (Float switch) to ST4 |
|
120V/60hz, 7 watts | Black (Common) | 1.1 k Ω |
1.13 ± .10 gpm at 20- |
| (This value assumes the float switch is |
120 psi |
| closed). |
Vent wax motor | Measure resistance from J6 Pin 1 |
120V with 1/4" | Purple (Vent) to ST4 Black (Common) 1.2 k Ω |
| |
actuation stroke |
|
within 60 seconds |
|
Dispenser wax motor | Measure resistance from J6 Pin 3 |
|
| Tan (Dispenser) to ST4 Black |
|
120V with 1/4" | (Common) | 2 k Ω |
actuation stroke |
|
|
within 60 seconds |
|
|
16023212 | 2 | May 2004 |
|
| ©2004 Maytag Services |