Component Specifications
!WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing, unless testing requires power.
Illustration | Component | Test Procedure |
| Results |
| Limit Thermostat | Close on Temperature drop @ 149°F |
|
|
|
| ± 7°F (Temp) | 0 Ω | = Closed |
|
| Open on Temperature drop @ 164°F |
|
|
|
| ± 4°F (Temp) | Infinite Ω = Open |
Sensor/Thermistor | 10KΩ ± 3% at 77°F and 2.4 k Ω ± |
|
|
| 6.5% at 140°F |
|
|
| J5 pin 1 - Orange (Temp) to J5 Pin 4 - | Infinite Ω = Open | |
| Red (Neutral) | ||
|
| 0 Ω | = Closed |
|
|
|
|
Heater/Heating | Measure resistance from ST1 |
|
|
Element | Red/Black (Heater) to ST11 White |
|
|
120v/60hz, 650 watts | (Common) | 16 Ω |
|
| (This value assumes the high limit | ||
± 5% in air, 830 watts |
| thermostat is closed). | |
± 5% in coldwater |
|
|
|
|
|
|
|
Drain Motor | Measure resistance from |
|
|
| ST6 Gray (Drain) to ST4 Black |
|
|
120v/60hz | (Common) | 25 Ω |
|
| See section “Motor Connections and |
|
|
| Diagram” for wiring contacts. |
|
|
May 2004 | 3 | 16023212 |
©2004 Maytag Services |
|
|