Maytag MDB7650AWQ, MDB7600AWB, MDB7650AWB, MDB7650AWS Illustration Component Test Procedure Results

Page 3

Component Specifications

!WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing, unless testing requires power.

Illustration

Component

Test Procedure

 

Results

 

Limit Thermostat

Close on Temperature drop @ 149°F

 

 

 

 

± 7°F (Temp)

0

= Closed

 

 

Open on Temperature drop @ 164°F

 

 

 

 

± 4°F (Temp)

Infinite = Open

Sensor/Thermistor

10K± 3% at 77°F and 2.4 k ±

 

 

 

6.5% at 140°F

 

 

 

J5 pin 1 - Orange (Temp) to J5 Pin 4 -

Infinite = Open

 

Red (Neutral)

 

 

0

= Closed

 

 

 

 

Heater/Heating

Measure resistance from ST1

 

 

Element

Red/Black (Heater) to ST11 White

 

 

120v/60hz, 650 watts

(Common)

16

 

 

(This value assumes the high limit

± 5% in air, 830 watts

 

thermostat is closed).

± 5% in coldwater

 

 

 

 

 

 

 

Drain Motor

Measure resistance from

 

 

 

ST6 Gray (Drain) to ST4 Black

 

 

120v/60hz

(Common)

25

 

 

See section “Motor Connections and

 

 

 

Diagram” for wiring contacts.

 

 

May 2004

3

16023212

©2004 Maytag Services

 

 

Image 3
Contents Technical Information- Dishwasher WeightIllustration Component Test Procedure Component SpecificationsIllustration Component Test Procedure Results Component Readings/Testing Resistance Check Points and Values Electrical DiagnosticsMotor Connectivity Wire harness Connection plugComponent Information Wiring DiagramMay Maytag Services Cycle Chart