6. MENU FUNCTIONS
Calibrate guide (3-5)
The Calibrate guide
To test the guide wire:
1. Place the R40Li in the charging station
2.Select Calibrate guide
mower will now leave the charging station, run a calibration process in front of the charging station and then follow the guide wire to the connection point with the boundary wire and then start mowing.
3.Check that the mower can follow the guide wire all the way to the connection point with the boundary wire.
The test has failed if the mower cannot follow the guide wire all the way to the connection point with the boundary wire. It is likely that the installation has not been carried out in accordance with the instructions in 3. Installation. Common errors are for instance that there is not enough open space to the left of the guide wire as seen facing the charging station or the guide wire is not laid at an angle on a steep slope. See 3.6 Installation of the guide wire.
Rectify the installation and run a new test with Calibrate guide
Reset user settings (3-6)
This function allows you to reset R40Li to the default settings it had when it left the factory.
1.Select Reset user settings in the menu and press OK. Enter the correct PIN code and press OK.
46 - English