Extron electronic GSS 100 manual Name display, MAC Address display, Internal Temperature display

Page 21

Name display

The read-only Name display shows either the factory default name or a customized name that can be assigned under RS-232 or Ethernet control. If the name is greater than eight characters, the display shows the first eight characters of the assigned name and then scrolls the name to the left to display the remaining characters of the name.

The factory default name is the product name (GSS-100-) plus the last three pairs of the MAC address (see the “Programming Guide“ and “HTML Control and IPL File Manager“ sections to assign a name).

MAC Address display

The read-only MAC Address display shows the hardcoded, factory assigned hardware address.

Internal Temperature display

The read-only Internal Temperature display shows the Fahrenheit and Celsius measurements for the GSS temperature.

CAUTION: Temperatures above 150 degrees Fahrenheit (65 degrees Celsius) are potentially damaging to the GSS.

Baud Rate submenu

The Baud Rate menu is read-only without further action. The menu shows the selected baud rate for the RS-232 port of the GSS. The default setting is 9600.

To change the baud rate, press and release the Take button. The baud rate display starts blinking, and can be adjusted by rotating the Adjust/Select knob.

NOTE: The baud rate is also selectable using SIS commands (see the “Programming Guide“ section).

IP address submenu

The read-only IP address menu is read-only without further action. The menu shows the IP address of the GSS. The factory default IP address is 192.168.254.254.

To change the IP address, one octet at a time, press and release the Take button. The first (most-significant) octet starts blinking, and can be adjusted by rotating the Adjust/Select knob. Repeatedly press and release the Take button to cycle through the four IP address octets, enabling them for editing, one at a time.

NOTE: The IP address is also selectable using SIS commands or the HTML pages (see

the “Programming Guide“ and “HTML Control and IPL File Manager

sections).

Exit menu

Press and release the Next button while in the Exit menu to return the LCD to the default display cycle.

GSS 100 Graphic Still Store • Operation 15

Image 21
Contents GSS Safety Instructions English Copyright  X! *X1&* X2* X2#* X2! CE Contents GSS 100 Graphic Still Store Contents About the GSS 100 Graphic Still Store About this GuideApproximate Image Space for BMP Files FeaturesRear Panel Connections Mounting the GSSSignal Connections Power ConnectionRemote Connections Ethernet connectionSerial connection RJ-45 connector wiringReset Button Operation Front Panel Controls and IndicatorsFront Panel Operations Power-on IndicationsMuting the Video Output Selecting an Image to DisplayMenu System Overview Switch Effect menuOutput Configuration menu Effect submenuDuration submenu RGB Delay submenu Resolution submenuSync format submenu Sync polarity submenuPass-Thru submenu Slide Show menuAdvanced menu Auto Switch and slide show submenuName display Internal Temperature displayMAC Address display Baud Rate submenuFront Panel Absolute Reset Front Panel Security Lockout Executive ModeProgramming Guide Simple Instruction Set Control SymbolsSwitch effect Power-upGSS-initiated Unsolicited Messages Image selectionAuto-switch and slide show control Output configurationHost-to-GSS Instructions Front panel locksError Responses TimeoutUsing the Command and Response Tables Command Ascii Command Response Additional description Command and Response Table for SIS CommandsOutput rate Command/Response Table for SIS CommandsEvent script control File management X4 = Device name Symbol definitionsIP and port setup commands Command and Response Table for IP-Specific SIS CommandsHtml Control IPL File Manager PC Configuration Configuring the HardwareGSS Configuration Configuring the GSS using the ARP commandGSS Response to Ping Request Configuring the GSS using a direct PC connection Opening the Embedded Web Pages Enter Network PasswordSystem Status Status TabSystem Settings Configuration TabIP Settings fields Unit Name fieldIP Address field Dhcp radio buttonsGateway IP Address field Subnet Mask fieldDate/Time Settings Fields Date/Time Settings fieldsVideo Settings Video SettingsPasswords PasswordsEmail Alerts Firmware UpgradeClick the Firmware Upgrade link see figure File Management File Management TabControl Control TabImages Tab Image SettingsUploading adding an image Deleting a stored imageSelecting a stored image Installing the IPL File Manager and Uploading Images Installing the IPL File ManagerUploading Image Files Select Startup Mode Window Special Characters Specifications Video inputVideo output Sync File loading timesMemory and image storage General Control/remote video processorPart Numbers Crimp tools and assorted connectorsMounting Options CablesTabletop Placement Mounting the UnitRack Mounting Furniture Mounting Under-Furniture MountingThrough-furniture mounting Extron Warranty
Related manuals
Manual 4 pages 49.96 Kb Manual 45 pages 22.45 Kb

GSS 100 specifications

Extron Electronics GSS 100 is a powerful yet compact audio signal distribution system designed to enhance the audio experience in various applications, from classrooms to corporate environments. Known for its reliability and performance, the GSS 100 serves as an essential component for signal management in modern AV systems.

One of the main features of the GSS 100 is its capability to distribute audio signals to multiple outputs while maintaining high fidelity. With the ability to handle both balanced and unbalanced signals, the GSS 100 can adapt to various audio sources and systems. This flexibility makes it suitable for a wide range of applications, including live events, presentation venues, and educational institutions.

The GSS 100 utilizes Extron’s advanced audio processing technology, which includes built-in audio mixing, equalization, and signal routing capabilities. Users can easily manage audio levels and blend multiple audio sources to create a seamless listening experience. This is particularly beneficial in environments where sound quality is paramount, allowing for adjustments that optimize the auditory experience for the audience.

Another characteristic that sets the GSS 100 apart is its intuitive user interface. The device features a straightforward control system, making it easy for users to manage and configure settings without extensive technical knowledge. Additionally, the unit is built for quick installation, with both rear and front panel connections for flexible installation options. This design consideration helps streamline setup time and minimizes disruption.

The GSS 100 also integrates seamlessly with other Extron and third-party products, enhancing its versatility in complex AV systems. With various input and output configurations, users can connect the GSS 100 to microphones, mixers, and amplifiers effortlessly. Its ability to connect to networked AV systems further extends its capabilities, enabling remote monitoring and control through software interfaces.

In conclusion, the Extron Electronics GSS 100 stands out as a premier audio signal distribution system that combines advanced technology with user-friendly features. Whether for educational purposes, corporate events, or live productions, the GSS 100 delivers reliable performance and exceptional audio quality, ensuring an optimal listening experience for any audience. As a result, it remains a popular choice among AV professionals seeking to elevate their systems with efficient and effective audio management solutions.