Maytag RCS10DA, RFS manual Interlock Switches, Control Panel Removal, Interlock Switch Removal

Page 27

Disassembly Procedures

To avoid the risk of electrical shock, personal injury, or death,

!WARNING disconnect power to oven and discharge the capacitors before following any disassembly procedure.

! CAUTION

Interlock Switches

 

Primary switch is operated by bottom latch arm.

A microwave leakage test must be performed anytime

Interlock Switch Removal

 

a door assembly is removed, replaced, disassembly, or

 

1. Disconnect power to oven and remove outer case,

adjusted for any reason.

(see "Outer Case" procedure).

 

 

 

 

2. Remove control panel, (see "Control Panel" section).

 

3. Test interlock switches before removing, (see testing

Control Panel Removal

procedures).

 

4. Disconnect and label wire connections.

1. Disconnect power to oven and remove outer case,

5. Remove mounting screws securing interlock switch to

(see "Outer Case" procedure).

unit chassis.

 

2. Disconnect and label wires from controller/timer.

 

6. Remove switches by carefully releasing locking tabs

3. Open oven door.

on switch bracket and tilting switches to remove from

4. Remove screw securing top of control panel to cavity.

switch bracket.

 

Lift control panel up and out to release tabs.

 

 

Tab

 

 

 

Monitor

NC

 

COM

 

Switch

 

 

NO

 

Primary

 

 

Switch

COM

 

 

 

Secondary

NO

 

Switch

 

 

 

 

COM

 

 

Tab

5.Replace component and reverse procedure to reassemble.

NOTE: After repairing the door or the interlock system, it is necessary to check the switch continuity before operating the oven.

!CAUTION

Before replacing a blown monitor fuse, test the primary interlock switch, secondary interlock switch, monitor switch, and power relay contacts for proper operation. If the monitor fuse is blown by a failed switch operation, all switches and controller must be

©2004 Maytag Services

16023293 Rev. 0

27

Image 27
Contents Service Service Support Center Recognize Safety Symbols, Words, and LabelsImportant Information Table of Contents Important Safety Information For commercial use only Read and Follow the specificImportant Safety Information Grounding Instructions Explanation WiringTest Procedures 2 Methods Servicing of Grounded ProductsUnpacking Equipment Equipment PlacementOven Features General InformationService Parts and AccessoriesModel Identification Condition Cause Remedy Troubleshooting ProceduresCondition Check Result Cause Remedy Troubleshooting Procedures Electronic Models Troubleshooting Procedures Electronic Models Trouble 4 Oven operates with little or no heat Troubleshooting Procedures Electronic Models Service Information Microwave Leakage Testing Troubleshooting Testing Procedures After verifying or replacing Pad Trace Measurement RLY TAB CN1 Power Test Insulated terminals Disassembly ProceduresDisconnecting Wire Terminals Outer CaseDoor Removal Door Assembly Door DisassemblyInterlock Switches Interlock Switch RemovalControl Panel Removal High Voltage Capacitor Removal Adjusting InterlocksHigh Voltage Capacitor DiodeFuse / Fuse Block / Filter Assembly TransformerMagnetron Blower Motor or Wheel Splatter Shield AntennaStirrer Motor Oven Light Removal Tray ReplacementMagnetron Thermal Cut-Out TCO Cavity Thermal FuseAppendix a QuickStartReferenceGuide Do not power spraySo...how do I use it? Digital Dial QTY 2X Pad some models Clean FilterQuick Start Reference Guide Do not power spray No metal pans

RFS, RCS, RCS10DA specifications

The Maytag RCS10DA, RCS, and RFS series are some of the most innovative and reliable appliances in the modern kitchen. With a focus on performance, efficiency, and user convenience, these models stand out in the crowded market of refrigerators and freezers.

The Maytag RCS10DA is designed to deliver outstanding cooling performance while keeping energy consumption in check. One of its standout features is the Twin Cooling System, which uses two separate airflow systems to maintain optimal humidity levels in both the refrigerator and freezer sections. This technology ensures that your foods stay fresher for longer by preventing the mixing of odors and moisture.

In addition to Twin Cooling, the RCS series is equipped with the PowerCold feature. This function is particularly helpful for quickly chilling items after grocery shopping or hosting large gatherings. With a simple press of a button, the refrigerator rapidly cools down to the desired temperature, ensuring that perishable items remain safe and fresh.

The RCS and RFS models boast adjustable shelving and organizational bins that provide maximum storage flexibility. The shelves are designed to accommodate taller items, and the door bins are deep enough to hold larger bottles and containers. Furthermore, these models feature LED interior lighting that not only enhances visibility but also consumes less energy compared to traditional bulbs.

Durability is another hallmark of Maytag appliances, and the RCS series is no exception. Constructed with heavy-duty materials and a robust design, these refrigerators are built to withstand the rigors of daily use. Additionally, many models come with a stainless steel finish that resists fingerprints and makes cleaning a breeze.

Energy efficiency is a critical aspect of modern appliances, and Maytag addresses this with Energy Star certification. The RCS and RFS models are designed to use less energy without compromising performance, thereby reducing utility bills and environmental impact.

In summary, the Maytag RCS10DA, RCS, and RFS series offer a suite of features and technologies that cater to the needs of today’s consumers. With innovations like the Twin Cooling System, PowerCold feature, adjustable shelving, and a commitment to durability and energy efficiency, these models are ideal choices for anyone looking to elevate their kitchen experience. Whether you require expansive storage or quick cooling solutions, Maytag provides reliable appliances designed to meet modern demands.