Maytag RCS10DA, RFS manual Grounding Instructions

Page 7

Important Safety Information

!WARNING

Precautions to be observed before and during servicing to avoid possible exposure to excessive microwave energy, or electrical shock disconnect power to oven.

Do not operate or allow oven to be operated with door open.

Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary:

Interlock operation

Proper door closing

Seal and sealing surfaces (arcing, wear, and other damage)

Damage to or loosening of hinges and latches

Evidence of dropping or abuse

Before turning on microwave power for any service test or inspection within the microwave generating compartments, check the magnetron, waveguide or transmission line, and cavity for proper alignment, integrity, and connections.

Any failed or misadjusted components in the interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired, replaced or adjusted by procedures described in this manual before oven is released to the consumer.

Check microwave leakage to verify compliance with the federal performance standard should be performed on each oven prior to release to the consumer.

!WARNING

To avoid risk of electrical shock, injury or death; make sure these grounding instructions are followed.

Grounding Instructions

!WARNING

Do not remove grounding prong when installing grounded appliance in a home or business that does not have three wire grounding receptacle, under no condition is grounding prong to be cut off or removed. It is the personal responsibility of the consumer to contact a qualified electrician and have properly grounded three prong wall receptacle installed in accordance with appropriate electrical codes.

!WARNING

To avoid the risk of electrical shock or death, do not alter the plug.

!WARNING

To avoid the risk of electrical shock or death, this equipment must be grounded.

This equipment MUST be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This oven is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.

Consult a qualified electrician or servicer if grounding instructions are not completely understood, or if doubt exists as to whether the equipment is properly grounded.

Do not use an extension cord. If the product power cord is too short, have a qualified electrician install a three- slot receptacle. This oven should be plugged into a separate 60 hertz circuit with the electrical rating as shown in the appropriate drawing. Models operate with a 120 supply voltage. When a microwave oven is on a circuit with other equipment, an increase in cooking times may be required and fuses can be blown.

NEMA 5-20R/5-20P

120V–20AMP

NEMA 5-15R/5-15P

120V–15AMP

©2004 Maytag Services

16023293 Rev. 0

7

Image 7
Contents Service Recognize Safety Symbols, Words, and Labels Service Support CenterImportant Information Table of Contents Important Safety Information For commercial use only Read and Follow the specificImportant Safety Information Grounding Instructions Explanation WiringTest Procedures 2 Methods Servicing of Grounded ProductsUnpacking Equipment Equipment PlacementOven Features General InformationParts and Accessories ServiceModel Identification Condition Cause Remedy Troubleshooting ProceduresCondition Check Result Cause Remedy Troubleshooting Procedures Electronic Models Troubleshooting Procedures Electronic Models Trouble 4 Oven operates with little or no heat Troubleshooting Procedures Electronic Models Service Information Microwave Leakage Testing Troubleshooting Testing Procedures After verifying or replacing Pad Trace Measurement RLY TAB CN1 Power Test Insulated terminals Disassembly ProceduresDisconnecting Wire Terminals Outer CaseDoor Removal Door Assembly Door DisassemblyInterlock Switch Removal Interlock SwitchesControl Panel Removal High Voltage Capacitor Removal Adjusting InterlocksHigh Voltage Capacitor DiodeTransformer Fuse / Fuse Block / Filter AssemblyMagnetron Antenna Blower Motor or Wheel Splatter ShieldStirrer Motor Oven Light Removal Tray ReplacementMagnetron Thermal Cut-Out TCO Cavity Thermal FuseAppendix a QuickStartReferenceGuide Do not power spraySo...how do I use it? Digital Dial QTY 2X Pad some models Clean FilterQuick Start Reference Guide Do not power spray No metal pans

RFS, RCS, RCS10DA specifications

The Maytag RCS10DA, RCS, and RFS series are some of the most innovative and reliable appliances in the modern kitchen. With a focus on performance, efficiency, and user convenience, these models stand out in the crowded market of refrigerators and freezers.

The Maytag RCS10DA is designed to deliver outstanding cooling performance while keeping energy consumption in check. One of its standout features is the Twin Cooling System, which uses two separate airflow systems to maintain optimal humidity levels in both the refrigerator and freezer sections. This technology ensures that your foods stay fresher for longer by preventing the mixing of odors and moisture.

In addition to Twin Cooling, the RCS series is equipped with the PowerCold feature. This function is particularly helpful for quickly chilling items after grocery shopping or hosting large gatherings. With a simple press of a button, the refrigerator rapidly cools down to the desired temperature, ensuring that perishable items remain safe and fresh.

The RCS and RFS models boast adjustable shelving and organizational bins that provide maximum storage flexibility. The shelves are designed to accommodate taller items, and the door bins are deep enough to hold larger bottles and containers. Furthermore, these models feature LED interior lighting that not only enhances visibility but also consumes less energy compared to traditional bulbs.

Durability is another hallmark of Maytag appliances, and the RCS series is no exception. Constructed with heavy-duty materials and a robust design, these refrigerators are built to withstand the rigors of daily use. Additionally, many models come with a stainless steel finish that resists fingerprints and makes cleaning a breeze.

Energy efficiency is a critical aspect of modern appliances, and Maytag addresses this with Energy Star certification. The RCS and RFS models are designed to use less energy without compromising performance, thereby reducing utility bills and environmental impact.

In summary, the Maytag RCS10DA, RCS, and RFS series offer a suite of features and technologies that cater to the needs of today’s consumers. With innovations like the Twin Cooling System, PowerCold feature, adjustable shelving, and a commitment to durability and energy efficiency, these models are ideal choices for anyone looking to elevate their kitchen experience. Whether you require expansive storage or quick cooling solutions, Maytag provides reliable appliances designed to meet modern demands.