Bunn TB6 Component Access, Control Thermostat, Location Control thermostat is located in the hood

Page 10

SERVICE

This section provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem.

WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by qualified service personnel. The brewer should be unplugged when servicing, except when electrical tests are re- quired and the test procedure specifically states to plug-in the brewer.

COMPONENT ACCESS

WARNING - Disconnect the brewer from the power source before the removal of any panel or the replace- ment of any component.

All components are accessible by the removal of the top cover, front inspection panel, and rear panel.

FIG. 10-1 COMPONENT ACCESS

CONTROL THERMOSTAT

FIG. 10-2 CONTROL THERMOSTAT

Location:

The control thermostat is located in the hood.

Test Procedures:

1.Disconnect the brewer from the power source.

2.Locate the blue wire on the control thermostat.

3.Check the voltage across the blue/black wire on the control thermostat and the white wire on the tank heater on 120V models or red wire on the tank heater on two wire 200V or 230V models with a voltmeter. Connect the brewer to the power source. The indication must be:

a)120 volts ac for two wire 120 volt models.

b)200 to 230 volts ac for two wire 200 or 230 volt models.

4.Disconnect the brewer from the power source.

If voltage is present as described, proceed to #5.

If voltage is not present as described, refer to the wiring diagrams and check the brewer wiring harness.

5.Locate the black wire on the control thermostat.

6.Gently remove the capillary bulb and grommet from the tank.

7.Check the voltage across the black wire of the control thermostat and the white wire on the tank heater on 120V models or red wire on the tank heater on two wire 200V or 230V models with a voltmeter when the control thermostat is turned fully clockwise. Connect the brewer to the power

(CONTINUED)

Page 10

41722 070209

 

Image 10 Contents
TB3/TB6 Series Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Contents Brew cycle will not start No water Probable Cause RemedyTo the brewer Probable Cause ProblemBrew cycle will not start Water is not hot Control Thermostat Tank Heater Reactions resulting in serious Inconsistent beverage level Surfaces can initiate corrosive LeaksSpitting or excessive steaming Dripping from sprayhead Refer to Service Timer for test- ing proceduresBeverage overflows dispenser Funnel Brewer is making unusal noises Dry coffee grounds remainPlumbing Lines Water Supply Brewer is making unusal noises Tank Heater Problem Probable Cause RemedyCont Tank heater Control Thermostat Component AccessLocation Control thermostat is located in the hood Disconnect the control thermostat wires Adjust the control thermostat as requiredRemove all wires from limit thermostat termi- nals Limit ThermostatTank Heater Disconnect the brewer from the power supply1680W-120V 1680W-100V 1680W-230V 29.0 33.7 Refer to -2 when reconnecting the wires Lighted ON/OFF Switch TB3/TB3QOrange light Switch Switch is located on the front control panelThrough four when the switch is in the oposite Position If continuity is present as described, replace the wiresStart Switches 37080.0001to T. StatInlet Valves BREW/DILUTION Timer TB3 & TB6 BREW/DILUTION Timer Triacs Triacs TH-1/MV-1 Brew solenoid TH-2/MV-2 Dilution solenoidTerminals ½ batch connector Digital Brew Timer TB3Q & TB6QWhite Red Neutral L2 Digital Timer Triacs Triacs MV-2 Brew solenoid output MV-1 LineSchematic Wiring Diagram TB3Q Volts AC Wire Single PhaseSchematic Wiring Diagram TB3, TB3B, TB3-LP Schematic Wiring Diagram TB3Q Schematic Wiring Diagram TB3Q W/SWEETENER & Empty BAG Detect Schematic Wiring Diagram TB6 Schematic Wiring Diagram TB6Q
Related manuals
Manual 11 pages 51.02 Kb